Laserfiche WebLink
I <br /> ED PROGRAM CONSOLIDATED FOO <br /> SITE#2705447/05447 <br /> PIPING <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> VI.PIPING CONSTRL CTION(Check all that apply) Page of <br /> PIPINGUNDERGROUND PIEING ABOVEGROUND <br /> SYSTEM TYPE PRESSURE ❑2.SUCTION ❑3.GRAVITY 458 ❑1.PRESSURE ❑2.SUCTION ❑3.GRAVITY 459 <br /> CONSTRUCTION/ ❑ 'SINGLE WALL ❑3.LINED TRENCH [:199.OTHER 460 ❑1.SINGLE WALL [:195.XERXES 462 <br /> MANUFACTURER DOUBLE WALL ❑95.XERXES [:12.DOUBLE WALL [399.OTHER <br /> MANUFACTURER 461 MANUFACTURER 463 <br /> ❑1.BARE STEEL ❑6.FRP COMPATIBLE w/100%METHANOL [:11.BARE STEEL ❑6.FRP COMPATIBLE W/100%METHANOL <br /> MATERIALS AND ❑2.STAINLESS STEEL ❑7.GALVANIZED STEEL ❑2.STAINLESS STEEL ❑7.GALVANIZED STEEL <br /> CORROSION ❑3.PLASTIC COMPATIBLE WITH CONTENTS ❑95.XERXES ❑3.PLASTIC COMPATIBLE WITH CONTENTS ❑8.FLEXIBLE(HDPE) ❑99.OTHER <br /> PROTECTION FIBERGLASS ❑8.FLEXIBLE(HDPE) ❑99.OTHER ❑4. FIBERGLASS ❑9.CATHODIC PROTECTION <br /> ❑5.STEEL W/COATING ❑9.CATHODIC PROTECTION 464 El 5. STEEL W/COATING ❑95. XERXES 465 <br /> VII.PIPING LEAK DETECTION(Check all that apply)(A description ojthe monitoring program shall be submitted to the local agency) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR LEAK, <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL ALARMS <br /> ALARMS <br /> ❑ 2. MONTHLY 0.2 GPH TEST 2. MONTHLY 0.2 GPH TEST <br /> ❑ 3. ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Check all that apply): <br /> ❑ 5 DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY ❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) ❑ 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> ❑ 7. SELF MONITORING ❑ 7. SELF MONITORING <br /> GRAVITY FLOW: GRAVITY FLOW(Check all that apply): <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPH) ❑ 8. DAILY VISUAL MONITORING <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING <br /> SECONDARILY CONTAINED PIPING PRESSURIZED PIPING(Check all that apply): <br /> PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(check one) <br /> (Check one) ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ c. NO AUTO PUMP SHUT OFF <br /> DISCONNECTION ❑ 11. AUTOMATIC LEAK DETECTOR <br /> ❑ c. NO AUTO PUMP SHUT OFF ❑ 12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR <br /> RESTRICTION SUCTION/GRAVITY SYSTEM: <br /> ❑ 12. ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> SUCTION/GRAVITY SYSTEM: EMERGENCY GENERATORS ONLY(Check all than apply) <br /> ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND <br /> VISUAL ALARMS ❑ 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR ❑ 17. DAILY VISUAL CHECK <br /> RESTRICTION <br /> ❑ 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT I.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4.DAILY VISUAL CHECK <br /> DATE INST LE 468 .CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 5.TRENCH LINER/MONITORING <br /> ❑ 3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS El6.NONE 469 <br /> IX.OWNER/OPERATOR SIGNATURE <br /> I cenify that the information provided herein is true and accurate to the best of my knowledge. <br /> SIG OF M12;12R,- <br /> OPERATOR DATE 470 <br /> NAME OV OWNER/OPERAT (print) 471 TITLED OWNER/OPERATOR 472 <br /> JANETTE M.THOMPSON FOR CIRCLE K STORES,INC. COMPLIANCE SPECIALIST <br /> Permit Number(For local use only) 473 Permit Approved(For local use only) 474 1 Permit Expiration Date(For local use only)475 <br />