My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1469
>
2300 - Underground Storage Tank Program
>
PR0231126
>
COMPLIANCE INFO_2004-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 1:03:59 PM
Creation date
6/23/2020 6:44:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2007
RECORD_ID
PR0231126
PE
2361
FACILITY_ID
FA0001570
FACILITY_NAME
UNITED # 5447
STREET_NUMBER
1469
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
08818030
CURRENT_STATUS
01
SITE_LOCATION
1469 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231126_1469 E HAMMER_2004-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
338
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONIT NG SYSTEMC RTIFIC TION <br /> e By All Jurisdictions Within the State of Califomi <br /> Authority Cited.Chapter 6.7, and Safety Code,Chapter 16,Division 3 Title 23, mia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: CONOCO PHILLIPS#2705447 City: STOCKTON CA Zip:95209 <br /> Site Address: 1469 E HAMMER LANE Contact Phone No: 478-1522 <br /> Date of Testing/Service: 08/06/2007 <br /> Facility Contact Person: MANAGER-TOM <br /> Make/Model of Monitoring System:TLS350 Work Order Number: 2250860 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: 91 Tank ID: 89 <br /> X In-Tank Gauging Probe. Model: VEEDER ROOT X In-Tank Gauging Probe. Model: VEEDER ROOT <br /> X Annular Space or Vault Sensor. Model: 407 Annular Space or Vault Sensor. Model: 407 <br /> X Piping Sump/Trench Sensor(s). Model: 208 X1Piping Sumpffrench Sensor(s). Model: 208 <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> X Mechanical Line Leak Detector. Model: LD2000 X Mechanical Line Leak Detector. Model: FX1V <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank OverfilVHigh-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> TanklD: 87 Tank ID: <br /> In-Tank Gauging Probe. Model: VEEDER ROOT In-Tank Gauging Probe. Model: VEEDER ROOT <br /> X Annular Space or Vault Sensor. Model: 407 Annular Space or Vault Sensor. Model: 407 <br /> X Piping Sump/Trench Sensor(s). Model: 208 X Piping Sump/Trench Sensor(s). Model: 208 <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> x1 Mechanical Line Leak Detector. Model: LD2000 X Mechanical Line Leak Detector. Model: FE STP-MLD-D <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> ispenser : 1-2 Dispenser ID: 3-4 <br /> X❑Dispenser Containment Sensor(s) Model:BEI 406 X Dispenser Containment Sensor(s) Model: BEI 406 <br /> RI Shear Valve(s). X Shear Valve(s) <br /> ®Dispenser Containment Float(s)and Chain(s). X Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> X❑Dispenser Containment Sensor(s) Model:BEI 406 X Dispenser Containment Sensor(s). Model:BEI 406 <br /> ® Shear Valve(s). Shear Valve(s). <br /> X Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9-10 Dispenser ID: <br /> X❑ Dispenser Containment Sensor(s) Model: BEI 406 Dispenser Containment Sensor(s). Model: <br /> FX-j Valve(s). Shear Valve(s). <br /> ❑X Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> "If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): System set-up X❑Alarm history report <br /> Technician Name(print): DOUG FALDE Signature: <br /> Certification No.: B34906 License.No.: <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 8501 N.MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 08/06/2007 <br /> Monitoring System Certification Page 1 of 3 Based on CA form dated 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.