My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1469
>
2300 - Underground Storage Tank Program
>
PR0231126
>
COMPLIANCE INFO_2008-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 1:24:34 PM
Creation date
6/23/2020 6:44:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2010
RECORD_ID
PR0231126
PE
2361
FACILITY_ID
FA0001570
FACILITY_NAME
UNITED # 5447
STREET_NUMBER
1469
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
08818030
CURRENT_STATUS
01
SITE_LOCATION
1469 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231126_1469 E HAMMER_2008-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
335
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 0 0 Page 4. <br />6. PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard ❑X Professional Engineer <br />El Other (Specify) <br />Test Method Used: F] Pressure ❑ Vacuum ❑X Hydrostatic <br />F__] Other (Specify) <br />Test Equipment Used: vplt <br />Equipment Resolution: vplt to gph <br />Sump # 4 DIE <br />Sump # 3 UNL <br />Sump # 2 PLU <br />Sump # 1 SUP <br />Sump Diameter: <br />4811 <br />4811 <br />4811 <br />4811 <br />Sump Depth: <br />7' <br />7' <br />71 <br />7 <br />Sump Material: <br />fiberglass <br />fiberglass <br />fiberglass <br />fiberglass <br />Height from Tank Top to Top of <br />1411 <br />1411 <br />1411 <br />1411 <br />Highest Piping Pentration: <br />Height from Tank Top to Lowest <br />13 It <br />1311 <br />1311 <br />1311 <br />Electrical Pentration: <br />Condition of sump prior to testing: <br />good <br />good <br />good <br />good <br />Portion of Sump Tested: 1 <br />1611 <br />1611 <br />1611 <br />16 It <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />XEYes ❑No❑N <br />Yes ❑N�N <br />Yes UN�N <br />0 Yes F] a <br />product and water)?* <br />Turbine shutdown response time: <br />2 - 5sec <br />2 - 5sec <br />2 - 5sec <br />2 - 5 s e c <br />Is system programmed for fail-safe <br />X ❑ Yes N N <br />❑ <br />❑ ^ <br />X Yes NOUN <br />X ❑ Yes N N <br />❑ <br />X Yes []No[_]NA <br />❑ <br />shutdown?* <br />Was fail-safe verified to be <br />Yes N N <br />❑ � <br />X Yes N N <br />❑ � <br />X ❑ Yes N N <br />❑ � <br />X Yes NoL_A <br />❑ ❑ <br />operational?* <br />_I`� <br />Wait time between applying <br />pressure/vacuum/water and starting <br />5min <br />5min <br />5min <br />5min <br />test: <br />Test Start Time: <br />10 :43 <br />10 : 3 8 <br />12 :08 <br />10 :2 0 <br />Initial Reading (R1): <br />7.334 <br />8.624 <br />7.055 <br />7.658 <br />Test End Time: <br />11: 13 <br />11:08 <br />12 : 3 8 <br />10 : 50 <br />Final Reading (RF ): <br />7.330 <br />8.624 <br />7.055 <br />7.633 <br />Test Duration: <br />3 Omin <br />3 Omin <br />3 Omin <br />3 Omin <br />Change inReading (RF -R1 ): <br />.000gph <br />.000gph <br />.000gph <br />.002gph <br />Pass/Fail Threshold or Criteria: <br />. 05gph <br />. 05gph <br />. 05gph <br />. 05gph <br />INEEMEM <br />Was sensor removed for testing? <br />s❑No❑NA <br />7EYe <br />EYes❑No❑NA <br />EMEM <br />Yes❑No❑NA <br />F1YesNo�T <br />Was sensor properly replaced and <br />functional <br />N NA <br />X Ye N NA <br />❑so cO <br />X Ye N NA <br />❑sF❑verified <br />X Yes N <br />after testing? <br />Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.