My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1469
>
2300 - Underground Storage Tank Program
>
PR0231126
>
COMPLIANCE INFO_2011-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2021 1:51:31 PM
Creation date
6/23/2020 6:44:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2012
RECORD_ID
PR0231126
PE
2361
FACILITY_ID
FA0001570
FACILITY_NAME
UNITED # 5447
STREET_NUMBER
1469
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
08818030
CURRENT_STATUS
01
SITE_LOCATION
1469 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231126_1469 E HAMMER_2011-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION (One form per UST) <br /> TYPE OF ACTION (Check one item only. For a UST closure or removal,complete only this section and Sections I,II,III,IV,and IX below) 430. <br /> ❑ 1.NEW PERMIT ❑ 3.RENEWAL PERMIT ® 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 430& 1 DATE EXISTING UST DISCOVERED: 4306. <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) I i -5 <br /> Gam, <br /> BUSINESS NAME(Same as Facility Name or DBA-Doing Business As) 3. <br /> CRLLC #2705447 <br /> BUSINESS SITE ADDRESS 103. CITY 104. <br /> 1469 E. Hammer Lane I Stockton <br /> IL TANK DESCRIPTION <br /> TANK ID l_-,!/4 rr .-� 432. TANK MANUFACTURER 433. TANK CONFIGURATION:THIS TANK IS 434. <br /> 1 Unknown ® 1.A STAND-ALONE TANK Complete one page for each <br /> ❑ 2.ONE IN A COMPARTMENTED UNIT compartment in the unit. <br /> DATE UST SYSTEM INSTALLED 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS IN THE UNIT 437. <br /> 3/31/1998 12,068 <br /> III. TANK USE AND CONTENTS <br /> TANK USE ® la.MOTOR VEHICLE FUELING ❑ Ib.MARINA FUELING ❑ Ic.AVIATION FUELING 439. <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Includes Used Oil) ❑ 5.EMERGENCY GENERATOR FUEL(HSC§25281.5(c)] <br /> ❑ 6 OTHER GENERATOR FUEL ❑ 95 UNKNOWN ❑ 99.OTHER(Specify): 439& <br /> ....... __. _.-. <br /> CONTENTS PETROLEUM: ® la.REGULAR UNLEADED ❑ lc.MIDGRADE UNLEADED ❑ lb.PREMIUM UNLEADED 440. <br /> ❑ 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM(Specify): 440& <br /> ........._. _._... ._..._ . ........ .......... <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ 11.OTHER NON-PETROLEUM(Specify): 4406. <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ® 2.DOUBLE WALL ❑ 95.UNKNOWN 443. <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ® 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444. <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 444x. <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ®3.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445. <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑99 OTHER(Specify) 445a <br /> OVERFILL PREVENTION ❑ 1.AUDIBLE&VISUAL ALARMS ❑ 2.BALL FLOAT 3.FILL TUBE SHUT-OFF VALVE 452. <br /> 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVEIMLL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE.PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑ 1.SINGLE WALL A•'2.DOUBLE WALL ❑ 99.OTHER 460. <br /> ....... _ <br /> SYSTEM TYPE l PRESSURE ❑ 2 GRAVITY ❑ 3 CONVENTIONAL__SUCTION ❑ 4.SAFE SUCTION 123 CCR§263(4a)(3)] 458. <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464. <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464& <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC <br /> 4646. <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464c. <br /> PIPING/TURBINE CONTAINMENT SUMP TYPE 1.SINGLE WALL ❑ 2 DOUBLE WALL 0.NONE 464d. <br /> VI. VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 46644eel. <br /> _ .............. <br /> VENT SECONDARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 464fl. <br /> VR PRIMARY CONTAINMENT ❑ 1 STEEL g. <br /> 4.FIBERGLASS ❑ 10 RIGID PLASTIC I 90 NONE ❑ 99 OTHER(Specify): 464 1 <br /> ....._.....__ ._ _...._... _.... _... <br /> __....... ....._._ _.___...._. .- _ _....- 46an." <br /> VR SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ® 90.NONE ❑ 99.OTHER(Specify): 464h1 <br /> -._._.._.. - _....._...-..._......__._�.._.....-_...._..... ...._......_....._.....__...__...._......---..._....._......_.....__...__....- .._.......__...---...._._...._.....__..._..._.__._......_..__....__...._........__._......._....._...._..__._... ......_......_....__......_..... <br /> 4641. <br /> VENT PIPING TRANSITION SUMP TYPE ❑ 1.SINGLE WALL ❑ 2.DOUBLE WALL ® 90.NONE <br /> _.... - __ <br /> RISER PRIMARY CONTAINMENT 1 STEEL E] 4 FIBERGLASS ❑ 10 RIGID PLASTIC 'a/90.NONE ❑ 99 OTHER(Specify) qC4 j: <br /> '19RISER SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ I0.RIGID PLASTIC M 90.NONE C] 99.OTHER(Specify): 446441,1. <br /> _....._....._....._..._....�__.-_....__..._.-_...__�..._ _...�_....�.�_.__...---�__.�..._._..._...__...__.._-..._....__..._ - ..._....._.....-.�__._._..._.-_._-._.._ <br /> FILL COMPONENTS INSTALLED ® 1.SPILL BUCKET 3.STRIKER PLATE/BOTTOM PROTECTOR ❑ 4.CONTAINMENT SUMP 45lac. <br /> VII. UNDER DISPENSER CONTAINMENT (UDC) <br /> CONSTRUCTION TYPE L SINGLE WALL ❑ 2.DOUBLE WALL 3.NO DISPENSERS ❑ 90.NONE 469a <br /> _...._......_...._... -....._....._... ._.....----._...._..__..... .__...._.....__..._.._.._.....__...................._.....__....._...... ..._....._......._.......__...__.._.....__.- <br /> --.....__..._.........__._.-_._.___......_.....-.-_-------.................__............_.......-_..._ _._-_..._.._. _. ... 4696. <br /> CONSTRUCTION MATERIAL .rr 1.STEEL 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 99.OTHER(Specify) 469c. <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT ❑ 6.ISOLATION 448. <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true, <br /> accurate,and' full com li al requirements. <br /> APPLICANT SIGNATURE DATE 470. <br /> 05�� <br /> APPLICANT NAME(print) Armen MkrtyAian 471, APPLICANT TITLE California Compliance Manager 472 <br /> UPCF UST-B Rev.(12/2007)-IR www.unidocs.org <br />