Laserfiche WebLink
MON116UNG SYSTEM CETIFI TION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: CRLLC#5447 Bldg.No.: <br /> Site Address: 1469 E.HAMMER LANE City: STOCKTON Zip: 95210 <br /> Facility Contact Person: ALLEN FAASS Contact Phone No.: (925)884-0800 <br /> Make/Model of Monitoring System: VEEDER-ROOT TLS-350 Date of Testing/Servicing: 7116/2012 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific a ui ment inspected erviced: <br /> Tank ID: 91 Tank ID: 89 <br /> Z In-Tank Gauging Probe. Model: MAG Z In-Tank Gauging Probe. Model: MAG <br /> Z Annular Space or Vault Sensor. Model: 409 Z Annular Space or Vault Sensor. Model: 409 <br /> Z Piping Sump/Trench Sensor(s). Model: 208 Z Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> Z Mechanical Line Leak Detector. Model: LD 2000 Z Mechanical Line Leak Detector. Model: LD 2000 <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> Z Tank Overfill/High-Level Sensor. Model: FLAPPER Z Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: 87 Tank ID: DIESEL <br /> Z In-Tank Gauging Probe. Model: MAG Z In-Tank Gauging Probe. Model: MAG <br /> Z Annular Space or Vault Sensor. Model: 409 Z Annular Space or Vault Sensor. Model: 409 <br /> Z Piping Sump/Trench Sensor(s). Model: 208 Z Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> Z Mechanical Line Leak Detector. Model: LD 2000 Z Mechanical Line Leak Detector. Model LD 2000 <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> Z Tank Overfill/High-Level Sensor. Model: FLAPPER Z Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> ❑Other(specify equipment type and model in Section Eon Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1/2 Dispenser ID: 3/4 <br /> Z Dispenser Containment Sensor(s). Model: 406 Z Dispenser Containment Sensor(s). Model: 406 <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 7/8 <br /> Z Dispenser Containment Sensor(s). Model: 406 Z Dispenser Containment Sensor(s). Model: 406 <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9/10 Dispenser ID: <br /> Z Dispenser Containment Sensor(s). Model: 406 ❑Dispenser Containment Sensor(s). Model: <br /> Z Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): Z System set-up ® Alarm history report <br /> Technician Name(print): RICHARD THOMAS Signature: z Ut___ <br /> Certification No.: 834022 License.No.: 803705 <br /> Testing Company Name: TANK-TEK ENVIRONMENTAL CORPORATION Phone No.:(707)446-6151 <br /> Testing Company Address: 607 ELMIRA ROAD,PMB 336, VACAVILLE, CA 95687 Date of Testing/Servicing: 7/1612012 <br /> Page 1 of 4 <br /> UN-036— www.unidocs.org Rev.01/17/08 <br />