Laserfiche WebLink
oPaU N c 2\ SAN 10 A Q U I N Environmental Health Department <br /> ._.�� OG <br /> Ln ,o - —COUNTY— Linda Turkatte, REHS, Director <br /> Greatness grows here. <br /> Kasey Foley,REHS,Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon,REHS <br /> Jeff Carruesco,REHS,RDI <br /> Rodney Estrada,REHS <br /> Willy Ng,REHS <br /> Muniappa Naidu,REHS <br /> October 10,2018 <br /> MATT THOMAS 3 <br /> CGRS INC <br /> 5444 DRY CREEK RD <br /> SACRAMENTO, CA 95838 <br /> Re: UNITED#5447 SR0079662 <br /> 1469 E HAMMER LN <br /> STOCKTON, CA 95210 <br /> The San Joaquin County Environmental Health Department(EHD)has completed the review of the <br /> application for a permit to(1)install five Encore deflector("drip pans")plates, (2)replace 91-octane direct <br /> bury spill and vapor containers with OPW double wall spill containers, (3)replace all four existing tank <br /> annular manways with larger 18"manways, (4)and replace three tank annular sensors(in the 89, 87,and <br /> diesel tanks)with the Veeder Root#409 sensors on the underground storage tank(UST)system at the <br /> above noted address. The permit has been approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control District for any <br /> applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Stacy Rivera at(209)468-3440 to arrange the following appointments(a 48-hour notice is <br /> required for inspection appointments). <br /> • Sensor functionality: Functionality of the monitoring system must be verified to ensure that <br /> monitoring has been restored to meet the requirements of Title 23 California Code of Regulations <br /> and the Health&Safety Code. If it is determined that a cold start is necessary, a copy of the <br /> alarm history shall be printed prior to performing the"cold start"of the monitoring system and <br /> made available at the time of EHD inspection. <br /> • Spill bucket test:Verify minimum 5-gallon capacity and pass a one hour hydrostatic test(or <br /> equivalent, in operating condition). Proper drainage must also be verified. <br /> • Corrosion protection:Verify corrosion protection for direct bury spill bucket prior to backfilling. <br /> • Verification of the dispenser footprints contained by the under dispenser containment sumps <br /> (UDCs) <br /> • Visual inspection of the piping within the dispensers <br /> Please be aware that the facility cannot operate the UST system prior to the EHD inspection <br /> and approval. <br /> Please be aware that the facility cannot receive fuel in the 91,89,87 and diesel tank prior to the <br /> EHD inspection and approval. <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />