My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-1996
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1612
>
2300 - Underground Storage Tank Program
>
PR0231127
>
COMPLIANCE INFO_1986-1996
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2021 12:21:10 PM
Creation date
6/23/2020 6:44:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-1996
RECORD_ID
PR0231127
PE
2361
FACILITY_ID
FA0003611
FACILITY_NAME
PARKWOODS GAS & FOOD
STREET_NUMBER
1612
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
07728002
CURRENT_STATUS
01
SITE_LOCATION
1612 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231127_1612 W HAMMER_1986-1996.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
529
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />LIQUID CONSTRUCTION, INC. <br />October 7, 1986 <br />Arco <br />P.O. Box 5811 <br />San Mateo, California 94402 <br />Attention: Carl Seward <br />Re: Arco 4548 <br />1512 Hammer Lane/Brentwood, Stockton, Calif. <br />Dear Mr. Seward: <br />• <br />RpsavZ1 <br />NOV 5 1986 <br />ENVIROMENTAL HEALTH <br />FERMIT/SERVICES <br />On October 1, 1986, a Petro Tite System Test was performed at <br />the above -referenced location. The test was performed by <br />Russell Knudsen, LCI Technician. The NFPA Code 329.02 criteria <br />for a tight system is a maximum loss of .05 gallons per hour. <br />Because of the almost infinite variables involved, this is not <br />intended to be a mathematical tolerance and is not the permission <br />of actual leakage. <br />During the stand -pipe test procedure, the internal liquid <br />hydrostatic pressure applied to the underground tank system is <br />generally two to three times greater than normal liquid storage <br />pressures. This increase in hydrostatic pressure will amplify <br />the indicated rate of leak accordingly. <br />SYSTEM TEST <br />Tank No. 1 - East <br />Size - 10,000 Gallons <br />Produc6- Unleaded <br />The to showed a plus .040 <br />Based on the above criteria, <br />mathematically tight. <br />gallons per hour. <br />we find the tank tested <br />Tank No. 2 - East Center <br />Size - 6,000 Gallons <br />Product - Super Unleaded <br />The test showed a plus .040 gallons per hour. <br />Based on the above criteria, we find the tank tested <br />mathematically tight. <br />1054 North 'J' Street • Post Office Box 1220 0 Tulare, California 93275 0 (209) 688-1980 <br />