My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-1996
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1612
>
2300 - Underground Storage Tank Program
>
PR0231127
>
COMPLIANCE INFO_1986-1996
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2021 12:21:10 PM
Creation date
6/23/2020 6:44:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-1996
RECORD_ID
PR0231127
PE
2361
FACILITY_ID
FA0003611
FACILITY_NAME
PARKWOODS GAS & FOOD
STREET_NUMBER
1612
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
07728002
CURRENT_STATUS
01
SITE_LOCATION
1612 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231127_1612 W HAMMER_1986-1996.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
529
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JANUARY 4, 1991 <br />BARGHAUSEN CONSULTING ENGINEERS, INC. <br />4612 ROSEVILLE ROAD, SUITE #103 <br />NORTH HIGHLANDS, CA 95660 <br />ATTN: PAUL WILTON <br />RE: ARCO FACILITY 10548 (JOB #3566) LOCATED AT 1612 W. HAMMER <br />LANE, STOCKTON, CA <br />I HAVE REVIEWED THE INSTALLATION PLAN YOU SUBMITTED FOR THE ABOVE <br />REFERENCED FACILITY AND FOUND THE FOLLOWING DEFICIENCIES: <br />1— YOU NEED TO INDICATE THE SPECIFIC U.L LISTED PIPING THAT WILL <br />BE USED FOR BOTH PRIMARY AND SECONDARY CONTAINMENT. <br />2— YOU NEED TO INDICATE WHICH RONAN SENSORS WILL BE USED IN THE <br />ANNULAR SPACE OF EACH TANK AS WELL AS THE SUMP AREA OF EACH <br />TANK. <br />3— YOU NEED TO INCLUDE A BALL CHECK ON THE PHASE I VAPOR RECOVERY <br />FILL PIPE OR DOUBLE CONTAIN AND CONTINUOUSLY MONITOR IT. <br />4— YOU NEED TO PROVIDE A DRAWING SPECIFICALLY INDICATING WHERE THE <br />ANNULAR SPACE MONITOR WILL BE FOR THE DOUBLE WALL FIBERGLASS <br />TANKS (NOT THE STEEL TANKS). <br />5— YOU NEED TO INDICATE WHAT TYPE OF OVERFLOW PROTECTION WILL BE <br />USED. YOU MUST USE A LIQUID LEVEL SENSOR WITH EITHER AN <br />AUTOMATIC SHUTOFF DEVICE (OPW 61 SO) OR AN ALARM TRIGGERED BY <br />THE LIQUID LEVEL SENSOR. <br />6— YOU NEED TO PROVIDE THE SPEC SHEETS FOR THE OVERFILL BOX THAT <br />WILL BE USED, WE DO NOT HAVE THEM IN THIS OFFICE. <br />7— YOU NEED TO SPECIFY WHICH FLEX PIPING WILL BE USED, TELEFLEX OR <br />TITELFLEX. <br />8— NO MONITORING PLAN WAS SUBMITTED, PLEASE HAVE FACILITY SUBMIT <br />ONE (I HAVE INCLUDED THE STATE REQUIREMENTS FOR THE MONITORING <br />PLAN WITH THIS LETTER). <br />9— THE RESPONSE PLAN WAS INADEQUATE, PLEASE BE SPECIFIC WHEN <br />ADDRESSING THE FOLLOWING ITEMS IN THE RESPONSE PLAN: <br />A) A DESCRIPTION OF THE PROPOSED METHODS AND EQUIPMENT TO BE <br />USED FOR REMOVING THE HAZARDOUS SUBSTANCE, INCLUDING THE <br />LOCATION AND AVAILABILITY OF THE REQUIRED EQUIPMENT, IF NOT <br />PERMANENTLY ON SITE, AND AN EQUIPMENT MAINTENANCE SCHEDULE <br />FOR THE EQUIPMENT LOCATED ON—SITE.* <br />
The URL can be used to link to this page
Your browser does not support the video tag.