My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2001
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1612
>
2300 - Underground Storage Tank Program
>
PR0231127
>
COMPLIANCE INFO_1997-2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2021 12:53:20 PM
Creation date
6/23/2020 6:44:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2001
RECORD_ID
PR0231127
PE
2361
FACILITY_ID
FA0003611
FACILITY_NAME
PARKWOODS GAS & FOOD
STREET_NUMBER
1612
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
07728002
CURRENT_STATUS
01
SITE_LOCATION
1612 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231127_1612 W HAMMER_1997-2001.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
328
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Y ' <br /> EsoV Cps. <br /> STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> 7 PERMANENTLY ON SITE <br /> MARK ONLY ❑ ,1.NEW..PERMIT a 3 RENEWAL PERMIT �. S CHANGE-OF.INFORMATION � � <br /> ONE ITEM 2 INTERIM PERMIT 4 AMENDED PERMIT 6 TEMPORARY TANK CLOSUREr,8 TANK REMOVE <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK 1.D.It 0 awf,A A t, B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAYNEAR) D. TANK CAPACITY IN GALLONS: <br /> II.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> A. [Z,1 MOTOR VEHICLE FUEL a 4 OIL B. C L__j 1a REGULAR UNLEADED a 3 DIESEL 6 AVIATION GAS <br /> 1b PREMIUM UNLEADED 4 GASAHOL 7 METHANOL <br /> El 2 PETROLEUM 80 EMPTY ,.,1 PRODUCT <br /> El 1c MIDGRADE UNLEADED E::] 5 JET FUEL 8 M85 <br /> 3 CHEMICAL PRODUCT 95 UNKNOWN 2 WASTE El 2 LEADED 0 99 OTHER(DESCRIBE IN ITEM D.BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF O 1 DOUBLE WALL F--] 3 SINGLE WALL WITH EXTERIOR LINER 5 INTERNAL BLADDER SYSTEM E:] 95 UNKNOWN <br /> SYSTEM may( 2 SINGLE WALL O 4 SINGLE WALL IN A VAULT ED 99 OTHER <br /> B. TANK I 1 BARE STEEL F-] 2 STAINLESS STEEL F] 3 FIBERGLASS O 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL F-1 r5 CONCRETE F-� 6 POLYVINYL CHLORIDE F-1 7 ALUMINUM 8 100% METHANOL COMPATIBLE W/FRP <br /> (Primary Tank) 9 BRONZE 10 GALVANIZED STEEL a 95 UNKNOWN 99 OTHER <br /> E" C.INTERIOR F-1 1 RUBBER LINED O 2 ALKYD LINING 3 EPDXY LINING a 4 PHENOLIC LINING <br /> LINING OR F-� 5 GLASS LINING I g'6 UNLINED F-1 95 UNKNOWN 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES_ NO— <br /> D.EXTERIOR 0 1 POLYETHYLENE WRAP F-� 2 COATING El 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION 5 CATHODIC PROTECTION E:l 91 NONE F�*5 UNKNOWN 0 99 OTHER <br /> SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENT�ON,EQUIPMENT INSTALLED(YEAR) <br /> E.SPILL AND OVERFILL,EtC. DROP TUBE YES «. NO- 1 PLATE YES NO DISPENSER CONTAINME YE NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A&k SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A 1 .BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> 1 MECHANICAL UNE LEAK 2 UNE TIGHTNESS 3 CONTINUOUS INTERSTITIAL 4 ELECTRONIC U _ <br /> NE 5 AUTOMATIC PUMP <br /> D. LEAK DETECTION DETECTOR a TESTING MONITORING LEAK DETECTOR SHUTDOWN ❑ 99 OTHER <br /> V.TANK LEAK DETECTION ] <br /> 1 VISUAL CHECK A!S ECONCIL2 MANUAL IATIONENTORY 3 MONITORING VADOZEa 4 AUTOMATGAUGING IC TANK 5 GROUND MONITORING TER 6 TETANK <br /> STING <br /> 7 MONITORING INTERSTITIAL D 8 SIR Q 9 WEEK LY MANUAL 10 MO TINLY TANK 0 95 UNKNOWN El 99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> 1.ESTIMATED DAT�LAST WMO/DAYNR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES a NO <br /> do <br /> -?r�I SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PEY, D TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> TANK OWNER'S NAME DATE <br /> .; (PRINTED 6 SIGNATURE) <br /> S +�3 <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF TH OUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# <br /> STATE I.D.4 m FM I I I I I 1 1 11111,7, 1 riI <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS.THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PLAN. FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br /> FORM B (6-95) <br />
The URL can be used to link to this page
Your browser does not support the video tag.