Laserfiche WebLink
W <br />D. Results of Testing/Servicin <br />Software Version Installed: <br />Yes <br />❑ No* <br />Is the audible alarm operational? <br />Yes <br />❑ No* <br />Is the visual alarm operational? <br />Ye <br />❑ No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />❑ No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipm]willnot <br />Yes <br />interfere with their proper operation? <br />❑ Yes <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. <br />—❑/No* <br />ld"N/A <br />operational? <br />Yes <br />❑ No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary conta <br />❑ N/A <br />monitoring system detects a leak, fails to operate, is electrically disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all that apply) ump/Trench Sensors; ❑ Dispenser Containment Sensors. <br />leaks failure/disconnection? es; ❑ No. <br />Did you confirm positive shut -down due to and sensor <br />ElYes <br />El No*. <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />CS N/A <br />mechanical overfill prevention. valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? % <br />❑ Yes* <br />No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />Ga'Nes* <br />C3No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />❑ Product; OrWater. If yes, describe causes. in Section E, below. <br />Yes❑ <br />No* <br />Was monitoring system set-up reviewed to ensure proper settings?. Attach set up reports, if applicable <br />CirYes <br />❑ —No* <br />Is all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, aescrioe now anu wncac ---- ••�-- - •.___ __ ____ __ <br />