My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1612
>
2300 - Underground Storage Tank Program
>
PR0231127
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2021 2:55:56 PM
Creation date
6/23/2020 6:44:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231127
PE
2361
FACILITY_ID
FA0003611
FACILITY_NAME
PARKWOODS GAS & FOOD
STREET_NUMBER
1612
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
07728002
CURRENT_STATUS
01
SITE_LOCATION
1612 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231127_1612 W HAMMER_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
427
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone.(209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Name: <br />Facility Address: <br />Date: <br />RKWOODS GAS & FOOD <br />1612 W HAMMER LN STOCKTON <br />May 07 2015 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />204 <br />CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br />An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be accessible <br />on site at all times. Immediately locate retain a copy on site. <br />cand <br />This is a repeat violation, Class IL <br />208 <br />CCR 2715 Designated operator monthly inspection reports not maintained on site for at least 12 months. <br />The April 2015 designated operator monthly inspection reports were not found on site. Designated operator monthly <br />inspection reports for the previous twelve months shall be retained on site. Locate and ensure that copies of the <br />previous twelve months of designated operator monthly inspection reports are maintained on site. Submit copies to <br />the EHD. <br />Class 11. wk -C -A e C'\ \ C 1� 1 I � fsm £ 1' <br />This is a repeat violation, <br />314 <br />CCR 2631(a) Primary containment not tight (pre -Jul 2003). <br />The union from the diesel in UDC 4 was leaking into the UDC during the time of inspection, indicating a leak in the <br />primary piping. All primary containment for the UST system must be tight. Immediately have a properly licensed, <br />trained, and certified contractor repair or replace the failed component and write a statement to the EHD when the <br />repair is complete. The service technician removed the diesel and placed in hazardous(r waste drum onsite. <br />BBnn <br />This is a repeat violation, Class 11. 1) M C r( X Cj I'� <br />323 <br />CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br />The 91 VMI line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of detecting <br />a 3 -gallon per hour leak at 10 psi. The service technician adjusted the leak detector, retested it, and it passed. <br />This is a minor violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by June 6, 2015 . <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />NOTES: <br />* Verified all sensors at lowest point. <br />Received by <br />Inspector: <br />Phone: <br />Date: <br />(initial): <br />FATINAH ZAREEF, REHS <br />(209) 953-7311 <br />05/07/2015 <br />Page 4 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.