Laserfiche WebLink
T LI <br />INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br />0.00 0.00 <br />Dipped Product Level: <br />tip Tankwfogy <br />Probe Water Level: -0.003 <br />-0.003 <br />TEST DATE: 03/16/01 <br />8900 SHOAL CREEK, BUILDING 200 <br />WORK ORDER NUMBER2215984 <br />CLIENT:WENDT CONSTRUCTION <br />AUSTIN, TEXAS 78757 (512) 451-6334 <br />SITE:CHEVRON <br />VacuTect Test Type: <br />Multiple tanks <br />VacuTect Probe Entry Point: <br />Fill <br />Tank ID: 1 1 <br />Tank manifolded: NO <br />Bottom to top fill in inches: <br />140.0 <br />Product: SUPREME <br />Vent manifolded: No <br />Bottom to grade in inches: <br />150.0 <br />Capacity in gallons: 12,141 <br />Vapor recovery manifolded: NO <br />Fill pipe length in inches: <br />44.0 <br />Diameter in inches: 96.00 <br />Overfill protection: YES <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: 392 <br />Overspill protection: YES <br />Stage I vapor recovery: <br />DUAL <br />Material: DW STEEL <br />Installed: ATG <br />Stage II vapor recovery: <br />BALANCE <br />CP installed on: <br />COMMENTS <br />Dipped Water Level: <br />0.00 0.00 <br />Dipped Product Level: <br />72.90 72.90 <br />Probe Water Level: -0.003 <br />-0.003 <br />Ingress Detected: Water N <br />Bubble N UllageN <br />Test time: <br />10:26-11:56 <br />Inclinometer reading: <br />1.00 <br />VacuTect Test Type: <br />Multiple tanks <br />VacuTect Probe Entry Point: <br />Fill <br />Pressure Set Point: <br />-1.20 <br />Tank water level in inches: <br />0.00 <br />Water table depth in inches: <br />154.00 <br />Determined by (method): <br />OBSERVATION PORT <br />Result: <br />PASS <br />COMMENTS <br />MAG PROBE DW DRY ANNULER <br />COMMENTS <br />Material: DW FIBERG <br />Diameter (in): <br />2.0 <br />Length (ft): <br />100.0 <br />Test psi: <br />50 <br />Bleedback cc: <br />70 <br />Test time (min): <br />30 <br />Start time: <br />10:07 <br />End time: <br />10:37 <br />Final gph: <br />0.000 <br />Result: <br />PASS <br />Pump type: <br />PRESSURE <br />Pump make: <br />FE PETRO <br />Make: <br />Model: <br />S/N: <br />Open time in sec: <br />Holding psi: <br />Resiliency cc: <br />Test leak rate ml/m: <br />Metering psi: <br />Calib. leak in gph: <br />Results: <br />New/passed Failed/replaced New/passed Failed/replaced <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />VEEDERROOT <br />L.L.D. <br />21 <br />189.0 <br />10 <br />3.00 <br />PASS <br />NOT <br />TESTED <br />Impact Valves Operational: YES <br />NOT <br />TESTED <br />NOT <br />TESTED <br />Printed 03/19/2001 17:28 <br />