COMPLIANCE INFO_1985-2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HUNTER
>
642
>
2300 - Underground Storage Tank Program
>
PR0231148
>
COMPLIANCE INFO_1985-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/26/2021 4:42:26 PM
Creation date
6/23/2020 6:44:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2003
RECORD_ID
PR0231148
PE
2361
FACILITY_ID
FA0000799
FACILITY_NAME
STOCKTON MOBIL #1
STREET_NUMBER
642
Direction
N
STREET_NAME
HUNTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13906035
CURRENT_STATUS
01
SITE_LOCATION
642 N HUNTER ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231148_642 N HUNTER_1985-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
396
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J'OAQUIN I.00_AT, HEALTH DISTRICT <br />SAMPLING PROTOCAL FOR ROUTINE TANK REMOVALS <br />The following represents minimum sampling criterion required for closure compliance. Soil <br />samples collected shall be representative of native soils beneath the tank's <br />invert [tank's bottom] at a collection depth not be exceed 2 - 4 feet. If contamination <br />is documented during closure an Unauthorized Release notification must be filled out and <br />submitted to SJLHD within 5 days. Section 2652, CCR. <br />WATER NOT PRESENT IN THE TANK PIT <br />TANK SIZE MINIMUM NUMBER OF LOCATION OF SOIL SAMPLES <br />SOIL SAMPLES I <br />At <br />w <br />k- - <br />1.000 allons S�tE- tank Fill p- ^�--.f tin <br />1000 - 10,000 allons TWO r tank One at each end of tank <br />gallons and up THREE OR MORE r <br />per tank§Wge�nera1Myys1pD�ace:d0along <br />he lengh of the tank <br />Piping ONE --my 20 L.FEET <br />WATER IS PRESENT IN•TANK PIT <br />TANK SIZE <br />MINIMUM NO. OF <br />SOIL SAMPLES <br />LOCATION OF SOIL <br />SAMPLES <br />MINIMUM NUMBER <br />OF WATER SAMPLES <br />10,000 GALLONS <br />1000 - 10,000 gallons <br />From wall next to <br />OR LESS <br />10,001 gallons and up <br />tank ends at soil/ <br />Ends and Middle and <br />(Single Tank) <br />TWOgroundwater <br />enerall spaced along <br />he length the tank <br />ONE <br />of <br />interface <br />GREATER THAN <br />From wall next to <br />ONE <br />10,000 GALLONS <br />tank ends.at soil/ <br />OR <br />groundwater <br />TANK CLUSTER <br />FOUR <br />interface <br />OTHER SPECIAL CONDITIONS <br />SLAB PRESENT IN TANK PIT <br />Soil samples shall be obtained beneath the slab within native soils. Penetration through <br />the obstruction will be required in order to collect the samples. [Physical removal of the <br />obstruction will then allow sampling according to the above conditions.] <br />TANK SIZE <br />MINIMUM NUMBER OF <br />SOIL SAMPLES <br />LOCATION OF SOIL SAMPLES <br />Center and ends or sides <br />Less than 1000 gallons <br />THREE per tank <br />1000 - 10,000 gallons <br />FIVE per tank <br />Center and ends or sides <br />10,001 gallons and up <br />FIVE OR MORE per <br />Ends and Middle and <br />tank <br />enerall spaced along <br />he length the tank <br />of <br />EH 23 047 12/88 <br />REVISED 1/89 <br />