Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Facility Name: Facility Address: Date: <br />SHOP N GO 3 4511 PACIFIC AVE, STOCKTON I February 27, 2017 <br />323 <br />1 HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />❑ V <br />❑ R <br />❑ COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V <br />❑ R <br />❑ COS <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V <br />❑ R <br />❑ COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V <br />❑ R <br />❑ COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V <br />❑ R <br />❑ COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />❑ V <br />❑ R <br />❑ COS <br />329 <br />HSC 25298 <br />Failed to comply with permanent closure requirements <br />❑ V <br />❑ R <br />❑ COS <br />330 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />❑ V <br />❑ R <br />❑ COS <br />401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑ V ❑ R ❑ COS <br />402 CCR 2643(d) Daily monitoring of suction pipe (pre -Jan 1984) not performed ❑ V ❑ R ❑ COS <br />403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) ❑ V ❑ R ❑ COS <br />404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) ❑ V ❑ R ❑ COS <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V <br />❑ R <br />❑ COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V <br />❑ R <br />❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑ V <br />❑ R <br />❑ COS <br />I Item # I Remarks I <br />103 HSC 25292.2 Current financial responsibility documents not submitted. <br />The Certification of Financial Responsibility documents submitted to the California Environmental Reporting System <br />(CERS) have not been signed by the owner or operator of the underground storage tanks. Current financial <br />responsibility documents are required to be submitted annually. Immediately log into CERS at <br />http://cers.calepa.ca.gov/, and upload the required documents. <br />This is a repeat violation, Class 11. <br />104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br />UST Facility Operating Permit is not current in CERS. The Board of Equalization number, 44040786, is closed and <br />not valid. Contact the Board of Equalization and get a valid number. Any change of information must be updated in <br />CERS within 30 days of the changes. Immediately log into CERS, update the required information, and submit for <br />review by the EHD. <br />This is a Class II violation. <br />FA0002480 PR0231216 SCO01 02/27/2017 <br />EHD 23-01 Rev. 09/22/16 Page 3 of 5 Underground Storage Tank Program OIR <br />