My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4511
>
2300 - Underground Storage Tank Program
>
PR0231216
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 4:22:00 PM
Creation date
6/23/2020 6:45:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231216
PE
2361
FACILITY_ID
FA0002480
FACILITY_NAME
SHOP N GO 3
STREET_NUMBER
4511
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11023011
CURRENT_STATUS
01
SITE_LOCATION
4511 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231216_4511 PACIFIC_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
376
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Facility Name: Facility Address: Date: <br />SHOP N GO 3 4511 PACIFIC AVE, STOCKTON I February 27, 2017 <br />Item # I Remarks <br />201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br />Maintenance and monitoring records for the last three years were not found on site. The test results from the 2015 <br />and 2016 Monitoring System Certification were not available during the inspection. These records shall be <br />maintained on site for at least three years. Monitoring records include: (1) date and time of all monitoring or <br />sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />equipment, ground water elevations, or other test results; (6) results of inventory readings and reconciliations. A <br />copy of the 2015 and 2016 test results were provided by the consulting firm to the facility during the inspection. <br />This was corrected on site. <br />This is a repeat violation, Class II. <br />313 HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product -tight. <br />Seepage was observed above the shear valves in under dispenser containment (UDC) 3-4 indicating a leak in the <br />primary piping. All primary containment for the UST system must be tight. Continue to monitor for seepage and if <br />the seepage persists, immediately have a properly licensed, trained, and certified contractor repair or replace the <br />failed components. <br />This is a minor violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by March 29, 2017. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br />THIS FACILITY BACK • COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT • W <br />meceiveo oy: Date: February 27, 2017 Inspector: Inspector Phone: <br />Printed Name and Title: VICKI MCCARTNEY, Senior REHS (209) 468-9852 <br />Rolly Supnet, Clerk <br />FA0002480 PR0231216 SCO01 02/27/2017 <br />EHD 23-01 Rev. 09/22/16 Page 5 of 5 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.