Laserfiche WebLink
SY EM SET-UP REPORT (Page 1) <br /> SYSTEM SETUP COMMUNICATIONS SETUP IN-TANK SETUP T 2:Premium_Unlaad <br /> MAY 2. 2012 8:12 All - - - - - - - - - - _ - - - - - - - - - - - PRODUCT CODE THERMAL COEFF : .000700 <br /> T 1 :Unls:aded-Regular TANK DIAMETER 89.50 <br /> PORT SETTINGS:. PRODUCT CODE A TANK PROFILE 4 FTS <br /> THERMAL COEFF : .000700 FULL VOL 11527 <br /> SYSTEM UNITS COMM BOARD 1 (RS-232) TANK DIAMETER 89.50 67.1 INCH VOL 9344 <br /> U.S. BAUD RATE 1200 TANK PROFILE 4 PTS 44.8 INCH VOL 5836 <br /> SYSTEM LANGUAGE PARITY ODD FULL VOL 11527 22.4 INCH VOL : 2271 <br /> ENGLISH STOP BIT 1 STOP 67.1 INCH VOL 9344 <br /> SYSTEM DATE/TIME FORMAT DATA LENGTH: 7 DATA 44.8 INCH VOL : 5836 <br /> MON DD YYYY HH:MM:SS xM RS-232 SECURITY 22.4 INCH VOL 2271 FLOAT SIZE: 4.0 IN. <br /> CODEDISABLED <br /> UUIK STOP 120 WATER WARNING 2.0 <br /> 9321 THORNTON RD. COMM BOARD : 2 (RS-232) FLOAT SIZE: 4.0 IN. HIGH WATER LIMIT: 3.0 <br /> STOCKTON.CA. .95207 BAUD RATE 9600 <br /> 209-478-7149 PARITY NONE WATER WARNING 2.0 MAX OR LABEL VOL: 11527 <br /> STOP BIT 2 STOP HIGH WATER LIMIT: 3.0 OVERFILL LIMIT 90% <br /> SHIFT TIME 1 DISABLED DATA LENGTH: 8 DATA 10374 <br /> SHIFT TIME 2 DISABLED RS-232 SECURITY MAX OR LABEL VOL: 11527 HIGH PRODUCT 95% <br /> SHIFT TIME 3 DISABLED CODE : DISABLED OVERFILL LIMIT 90% 10950 <br /> SHIFT TIME 4 DISABLED 10374 DELIVERY LIMIT 14% <br /> COMM BOARD : 3 {EDIM ) HIGH PRODUCT 95% 1651 <br /> TANK PER TST NEEDED WRN RS-232 SECURITY 10950 <br /> DISABLED CODE : DISABLED DELIVERY LIMIT 14% LOW PRODUCT 500 <br /> TANK ANN TST NEEDED WRN 1646 LEAK ALARM LIMIT: 99 <br /> DISABLED COMM BOARD 5 {S-NAT ) SUDDEN LOSS LIMIT: 99 <br /> BAUD RATE 9600 LOW PRODUCT 500 - TANK TILT 0.21 <br /> LINE RE-ENABLE METHOD PARITY NONE LEAK ALARM LIMIT: 99 PROBE OFFSET 0.00 <br /> PASS LINE TEST STOP BIT : 2 STOP SUDDEN LOSS LIMIT: 99 <br /> DATA LENGTH: 8 DATA TANK TILT 0.44 <br /> LINE PER'TST NEEDED WRN RS-232 SECURITY PROBE OFFSET 0.00 SIPHON MANIFOLDED TANKS <br /> DISABLED CODE : DISABLED TO: NONE <br /> LINE ANN TST NEEDED WRN DTR NORMAL STATE: HIGH LINE MANIFOLDED TANKS <br /> DISABLED SIPHON MANIFOLDED TANKS TO: NONE <br /> TO: NONE <br /> PRINT TC VOLUMES AUTO TRANSMIT SETTINGS: LINE MANIFOLDED TANKS <br /> ENABLED TO: NONE LEAK f"IIN PERIODIC: 0% <br /> AUTO LEAK ALARM LIMIT 0 <br /> TEMP COMPENSATION DISABLED PERIODIC TEST TYPE <br /> VALUE (DEG F ) : 60.0 AUTO HIGH WATER LIMIT LEAK MIN PERIODIC: 0% STANDARD <br /> STICK HEIGHT OFFSET DISABLED 0 <br /> DISABLED AUTO OVERFILL LIMIT PERIODIC TEST TYPE PERIODIC TEST FAIL <br /> ULLAGE: 90% DISABLED STANDARD ALARM DISABLED <br /> AUTO LOW PRODUCT <br /> H-PROTOCOL DATA FORMAT DISABLED PERIODIC TEST FAIL GROSS TEST FAIL <br /> HEIGHT AUTO THEFT LIMIT ALARM DISABLED ALARM DISABLED <br /> DAYLIGHT SAVING TIME DISABLED <br /> ENABLED AUTO DELIVERY START GROSS TEST FAIL PER TEST AVERAGING: OFF <br /> START DATE DISABLED ALARM DISABLED <br /> MAR WEEK 2 SUN AUTO DELIVERY END TANK TEST NOTIFY: OFF <br /> START TIM£ DISABLED PER TEST AVERAGING:: OFF <br /> 2:00 AM AUTO EXTERNAL INPUT ON TNK TST SIPHON BREAKOFF <br /> END DATE DISABLED TANK TEST NOTIFY: OFF <br /> NOV WEEK 1 SUN AUTO EXTERNAL INPUT OFF DELIVERY DELAY 5 MIN <br /> END TIME DISABLED TNK TST SIPHON BREAKOFF PUMP THRESHOLD 10.00% <br /> 2:00 AM AUTO SENSOR FUEL ALARM <br /> DISABLED DELIVERY DELAY 5 MIN <br /> RE-DIRECT LOCAL PRINTOUT AUTO SENSOR WATER ALARM PUMP THRESHOLD 10.00% <br /> DISABLED DISABLED <br /> AUTO SENSOR OUT ALARM <br /> EURO PROTOCOL PREFIX DISABLED <br /> S <br /> 0 2012 Walton Engineering,Inc. <br />