My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2012 DOUBLE CHECK
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
9321
>
2300 - Underground Storage Tank Program
>
PR0231261
>
COMPLIANCE INFO_2009-2012 DOUBLE CHECK
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 1:56:44 PM
Creation date
6/23/2020 6:45:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2012 DOUBLE CHECK
RECORD_ID
PR0231261
PE
2361
FACILITY_ID
FA0002890
FACILITY_NAME
QUIK STOP MARKET #2120*
STREET_NUMBER
9321
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
080-180-05
CURRENT_STATUS
01
SITE_LOCATION
9321 N THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231261_9321 N THORNTON_2009-2012 DOUBLE CHECK.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
287
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SY EM SET-UP REPORT (Page 2) <br /> T 2:PI"eMjL4rti_UnIe6U LIQUID SENS1R SET_iP <br /> PRODUCT CODE B _ _ _ _ _ _ _ _ _ _ _ _ EVR ISD SETUP <br /> THERMAL COEFF : .000700 <br /> TANK DIAMETER 09.50 L 1 :91 ANI'•IULHR <br /> TANS. PROFILE 4 FTS DUAL POINTH';'URCS'TriTll <br /> FULL VOL 1 153^ CATEGORYAIVhIULAR SPH :E E;IR TYPE: BALANCE <br /> 67.1 INCH VOL 9344 <br /> 44.0 INCH VOL 58,36 BALANCE pJ07ZLE T':'PE <br /> 22.4 INCH VOL 2271 VST <br /> L :87 ANNULAR <br /> DUAL POINT H 'DR( STtiT I C �IAPOR P RCICESSOR TYPE <br /> FLOAT SIZE: 4.0 I N. I_:ATEG;,�R'Y : HNNULHR SPAI_'E FEEDER-ROO'T POLISHER <br /> WATER WARNIhUa 2.0 <br /> HIGH WATER LIMIT: 3.0 ANALYSIS TIMES <br /> L 3:91 STP SUHP TIME: 10:00 AM <br /> Nlr'i`rC OR LABEL 11'OI.: 1152', TRI-STATE (SINGLE FLOAT) DELAY MINUTES: i <br /> OVERFILL LIMIT 90% C'HTEGORY : STP =•UNIP <br /> 10:374 <br /> 1374 <br /> HIIaH PRODUCT 95`P ACCEPT HIGH ORVR: <br /> 10950 L 4:87 STP SUMF DISABLEU <br /> DELIVERY LIMIT 14`: TRI-STATE ;S I WGLE FLC AT i <br /> 1651 CATEGOR'r STP' SUMP ISD HOSE TABLE <br /> ID FP FL HL HH RR <br /> LOW PRODUCT 500 _ ---------------_------- <br /> LEAY ALARM LIMIT: 99 01 01 01 02 01 UJ <br /> SUDDEN LUSS LIMIT: 99 'OUTPUT RELA`i SETUP _ 02 03 0'= 02 01 UU <br /> TANK TILT 0.21 0:3 63 03 02 02 UU <br /> PROBE OFFSET 0.00 R 1 :91 STP 04 04 04 02 02 UU <br /> TYPE: <br /> SIPHON MAN I FOLDED TANKSSTAI:aIiHRD ISD A I RFLOW METER MHP <br /> TO: NONE NORMALLY (-LOSED ID SERIAL NUM LABEL <br /> LINE MANIF-)LDED TANKS THNK 0: - ------------------- <br /> ---- <br /> TO: NONE - 1 ''8091 DISI 1-'2 A <br /> 2 ^_8074 DISF' 3-4 H <br /> LEAP, M I N PER I'OD I O:y LIQUID SENSOR HLht:3 <br /> 0 <br /> L 3:FUEL ALARM ISE, FUEL GRADE HOS, <br /> cE MAP <br /> ' <br /> PERIODIC TEST TYPE L 3:SENSOR OUT HLHPM 1 3 4 <br /> STANDARD L 3:5HarRT ALARM FP HHH HHH MHH HHH AH <br /> --------------------------- <br /> PERIODIC.' TEST FAIL ISD SITE ALARI°IS 01 001 401 201 9 U 1 <br /> I311 GROSS PRES FAIL L <br /> ALARM D I SHBLED 0'2 202 3i=r2 902 U U 1 <br /> ISD DEGRD PRES FAIL 03 203 303 903 U U <br /> GROSS TEST FAIL ISD VAPOR LEAK FA I L 04 '' 04 304 904 U l: <br /> ALARM DISABLED ISD VP FRES FAIL <br /> ISD VF STATUS FAIL <br /> PER TEST AI,+`ERHU I NG: OFF PMI:' SETUP <br /> ISD H11E£ HLAkf")1' <br /> TANK TEST NOTIFY: OFF ALL:FLU6,I COLLECT FAIL PMC VERSION: 01 .02 <br /> R • :8r STP VAPOR PROCESSOR T'IPE <br /> TNK TST SIPHON BREAK:OFF T:'PE: =ELDER-ROOT POLI"HER <br /> DELIVERY DELA';' S MIN STANDARD <br /> PUMP THRESHOLD 10.00% NORNIALL,, i`.LOSED <br /> TANK 9: 1 <br /> LEAK TEST METHOD <br /> - - - - - - - - LIQUID SEh:SCIR HLh�1 <br /> TEST ON DATE : FiLL TANK L 4:FUEL HLARM <br /> OCT 9, 2005 L 4::SENSCIR OUT ALARM <br /> START TIME : D I SHBLED L 4:;HURT ALARM SOFTWARE REV I S:I ON LEVEL <br /> TEST RATE :0.'2'0 GAL,•HP <br /> ',F 329.'l1 <br /> DURATION 2 F0URS ISD SITE Abm0i5 SOFTWAREO 34c._-T2:;-1013--B <br /> ISD GROSS FRES FA I L CREr iTED - 09,U 1 .'-d9.15.44 <br /> TST EHRL'i' STOP:DISABLED ISD DEGRD PRES FAIL <br /> ISD VAPOR LEAK FAIL S-110DULEu 330160--01-14-.5 <br /> LEAK TEST REPORT POOH iLT I SD VP PRES Fra I L SYSTEM FEATURES: <br /> ISD VP STATUS FAIL PERICJD[C IN-TANK TEST£. <br /> ANNUAL IN-TANK TESTS, <br /> ISD HOSE ALARMS 150 <br /> ALL:FLOW COLLECT FAIL <br /> 2011 Walton Engineering,Inc. <br />