My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018 DOUBLE CHECK
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
9321
>
2300 - Underground Storage Tank Program
>
PR0231261
>
COMPLIANCE INFO_2013-2018 DOUBLE CHECK
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 2:01:09 PM
Creation date
6/23/2020 6:45:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018 DOUBLE CHECK
RECORD_ID
PR0231261
PE
2361
FACILITY_ID
FA0002890
FACILITY_NAME
QUIK STOP MARKET #2120*
STREET_NUMBER
9321
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
080-180-05
CURRENT_STATUS
01
SITE_LOCATION
9321 N THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231261_9321 N THORNTON_2013-2018 DOUBLE CHECK.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
248
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Overfill Prevention Inspection - OPW 61 and 71 Series Devices <br /> Date: 9/26/2018 <br /> Owner: <br /> Facility:Quik Stop!#120 <br /> OPW Overfill Model Number: 61 SO 111 SO <br /> Part 1 - ropereight Setting Calculation C(9 <br /> Tank 1 Tank 2 Tank 3 Tank <br /> Maximum Tank Volume Per; A Gallons 11527 11527 <br /> Max shut off requirement for flapper is 05�, s 95% 95 .95 <br /> Multiply Max tank volume by 95% c Gallons 10951 10951 <br /> Use tank chart or ATG to determine height of to[aches 80 1/2" 80 1/2" <br /> calculated volume <br /> Measure top of fill riser threads,or face seal Inches 34 1l$" 33 <br /> ada ter <br /> Tank diameter(From Tank Chart) r Inches 89 3/4" 89 3/4" <br /> Upper Tube in Tank(Cr)F-D=G G Inches 9 1/4" 9 1/4" <br /> Subtract 2"from upper tube in tank G-2"= K K Inches 7 1/4" 7 1/4" <br /> Calculated minimum upper tube length(t} I Inches 41 3/8" 40 1/4" <br /> K+E=I <br /> Actual measured upper tube length(Without J Inches 43 1/2" 40 1/4" <br /> fill adapter)(J) <br /> Part 2- Device Certification Criteria Evaluation <br /> Does the overfill prevention device meet the 95�27rr <br /> requirement? <br /> Yes Yes <br /> Is the actual measured upper tube length 6.5 inches or Yes Yes <br /> more than the fill riser?(J must he 6.5"or snore than E) <br /> Does the overfill prevention device function as required'? <br /> (Imspect the device for damage,contamination, freedom of Yes Yes <br /> movement,weakening due to wear and corrosion) <br /> Device Overfill Certification PASS/ FAIL Pass Pass <br /> Drop Tube Testing PASS /FAIL Pass Pass <br /> Technician certifies hat the device is operationally compliant, <br /> Signature of Technicia Date: 9/26/18 <br /> Technician's Name:duan aure <br />
The URL can be used to link to this page
Your browser does not support the video tag.