My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1992-2001
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ACKERMAN
>
1725
>
2300 - Underground Storage Tank Program
>
PR0231309
>
COMPLIANCE INFO_1992-2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2022 2:04:30 PM
Creation date
6/23/2020 6:45:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1992-2001
RECORD_ID
PR0231309
PE
2361
FACILITY_ID
FA0003756
FACILITY_NAME
KISHIDA, GEORGE INC
STREET_NUMBER
1725
STREET_NAME
ACKERMAN
STREET_TYPE
DR
City
LODI
Zip
95240
APN
06219001
CURRENT_STATUS
01
SITE_LOCATION
1725 ACKERMAN DR
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231309_1725 ACKERMAN_1992-2001.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
538
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TEST DATE: 03/21/01 <br />CLIENT: KISHIDA TRUCKING <br />Tank ID: 1 1 <br />Product: BLEND <br />Capacity in gallons: 15,000 <br />Diameter in inches: 112.00 <br />Length in inches: 355 <br />Material: DW FIBERG <br />COMMENTS <br />PSI at tank bottom: <br />Fluid level in inches: <br />UFT/OFT: <br />Fluid volume in gallons: <br />Tank water level in inches: <br />Test time: <br />Number of thermisters: <br />Specific gravity: <br />Water table depth in inches: <br />Determined by (method): <br />Leak rate in gph: <br />Result: <br />COMMENTS <br />Test time: <br />Ullage volume: <br />Ullage pressure: <br />Results: <br />TANK INFORMATION AND <br />8900 SHOAL CREEK, BUILDING 200 <br />AUSTIN, TEXAS 78757 (512) 451-6334 <br />Tank manifolded: No <br />Vent manifolded: No <br />Vapor recovery manifolded: No <br />Overfill protection: yES <br />Overspill protection: yEs <br />Installed: ATG <br />CP installed on: / <br />WORK ORDER NUMBER: 2216061 <br />SITE: KISHIDA TRUCKING <br />Bottom to top fill in inches: 112.0 <br />Bottom to grade in inches: <br />Fill pipe length in inches: <br />Fill pipe diameter in inches: <br />Stage I vapor recovery: DUAL <br />Stage II vapor recovery: BALANCE <br />New/passed Failed/replaced New/passed Failed/replaced <br />L.D. #1 L.Q. #1 L.D. #2 L.D. #2 <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: NOT <br />Flow rate (cfh): TESTED <br />Time of test 2: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 3: <br />Temperature: <br />Flow rate (cfh): <br />COMMENTS <br />Diameter (in): <br />Length (ft): <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />Test 1: Start time: <br />Finish psi: <br />Vol change cc: <br />Test 2: Start time: <br />Finish psi: <br />Vol change cc: <br />Test 3: Start time: <br />Finish psi: <br />Vol change cc: <br />Final gph: <br />Result: <br />Pump type: <br />Pump make: <br />COMMENTS <br />DW FIBERG <br />2.0 <br />100.0 <br />NOT NOT <br />TESTED TESTED <br />TOKHEIM <br />MV <br />4942 <br />3.00 <br />22 <br />100 <br />189.0 <br />10 <br />3.00 <br />PASS <br />NOT NOT <br />TESTED TESTED <br />PRESSURE <br />RED JACKET <br />Impact Valves Operational: UNKNOWN <br />Make: <br />RED JACKET <br />Model: <br />FXIOV <br />S/N: <br />4358 <br />NOT <br />Open time in sec: <br />2.00 <br />TESTED <br />Holding psi: <br />29 <br />Resiliency cc: <br />20 <br />Test leak rate ml/m: <br />189.0 <br />Metering psi: <br />10 <br />Calib. leak in gph: <br />3.00 <br />Results: <br />PASS <br />COMMENTS <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: NOT <br />Flow rate (cfh): TESTED <br />Time of test 2: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 3: <br />Temperature: <br />Flow rate (cfh): <br />COMMENTS <br />Diameter (in): <br />Length (ft): <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />Test 1: Start time: <br />Finish psi: <br />Vol change cc: <br />Test 2: Start time: <br />Finish psi: <br />Vol change cc: <br />Test 3: Start time: <br />Finish psi: <br />Vol change cc: <br />Final gph: <br />Result: <br />Pump type: <br />Pump make: <br />COMMENTS <br />DW FIBERG <br />2.0 <br />100.0 <br />NOT NOT <br />TESTED TESTED <br />TOKHEIM <br />MV <br />4942 <br />3.00 <br />22 <br />100 <br />189.0 <br />10 <br />3.00 <br />PASS <br />NOT NOT <br />TESTED TESTED <br />PRESSURE <br />RED JACKET <br />Impact Valves Operational: UNKNOWN <br />