My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ACKERMAN
>
1725
>
2300 - Underground Storage Tank Program
>
PR0231309
>
COMPLIANCE INFO_2002-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2022 3:24:31 PM
Creation date
6/23/2020 6:45:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2012
RECORD_ID
PR0231309
PE
2361
FACILITY_ID
FA0003756
FACILITY_NAME
KISHIDA, GEORGE INC
STREET_NUMBER
1725
STREET_NAME
ACKERMAN
STREET_TYPE
DR
City
LODI
Zip
95240
APN
06219001
CURRENT_STATUS
01
SITE_LOCATION
1725 ACKERMAN DR
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231309_1725 ACKERMAN_2002-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-r <br />MON*ORING SYSTEM CERTIFOATION <br />G�IV / <br />For Us, B) '411J111_iS(1iC1i017S 1471hin the Slide of C'crlifbr-niu <br />tl a/horih% C'i1ed: C11C7�7(L'/' 6. %, l(ect/Ih aad SufeltC <br />' 'oc1e; C'hapler 16, Division 3, 7ille 23, Culifbrnia Code o &pawiolls v <br />This form trust be used to document testing and servicing of monitoring equipment. A separate certift r re of be <br />prepared for each monitoring system control panel by the technician who performs the work. A copy of this vided to <br />the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regu <br />within 30 days of test date. <br />A. General Information <br />Facility Narne: <br />Site Address: / %/_5 <br />f®Ztt6kI <br />Bldg. No.: <br />City: _ Labr zip: �?.� Gr� <br />Facility Contact Person: lit A f Contact Phone No.: ( GU`/+ <br />Make/Model of Monitoring System: t1 eb% (- 015 L Date of Testing/Servicing: /1 / _T /6 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />Tanis ID: Ty fk k L l <br />Tank ID: <br />.& In -Tank Gauging Probe. Model: MJAL.j <br />❑ In -Tank Gauging Probe. Model: <br />Ok Annular Space or Vault Sensor. Model: Is (pL_v t <br />❑ Annular Space or Vault Sensor. Model: <br />Piping Sump / Trench Sensor(s). Model: LS ` 5<� <br />❑ Piping Sump / Trench Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model: <br />A Mechanical Line Leak Detector. Model:��-) �fj� <br />❑ Mechanical Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Other (specify equipment type and model in Section E on Pa a 2). <br />❑ Other (specify equipment t e and model in Sectio4 E on Pae 2). <br />Tank ID: V 11'eilr f- L - <br />Tank ID: <br />IR In -Tank Gauging Probe. Model: ljL7 <br />❑ In -Tank Gauging Probe. Model: <br />❑ Annular Space or Vault Sensor. Model: <br />❑ Annular Space or Vault Sensor. Model: <br />Piping Sump /Trench Sensor(s). Model: [ L <br />❑ Piping Sump / Trench Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model: <br />Q Mechanical Line Leak Detector. Model: <br />❑ Mechanical Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. . Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Other (s ecif a ui ment type and model in Section Eon Pa a 2). <br />❑ Other (s eci a ui ment type and model in Section E on Pa 2). <br />Dispenser ID: f <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). Model: <br />C3 Dispenser Containment Sensor(s). Model: <br />Shear Valve(s). <br />❑ Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). Model: <br />❑ Dispenser Containment Sensor(s). Model: <br />PUliear Valve(s). <br />❑ Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 0 41U.4 A 1 Dispenser ID: <br />Dispenser Containment Sensor(s). Model: EI 'Dispenser Containment Sensor(s). Model: _ <br />Shear Valve(s). ❑ Shear Valve(s). <br />2LPispenser Containment Float(s) and Chain(s). ❑ Dispenser Containment Float(s) and Chain(s). <br />*Ifthe facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br />manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br />information is correct and a Plot Phan showing the layout of monitoring equipment. For any equipment capable of generating such <br />reports, I have also attached a copy of the report; (check all that app/j,): US.yst farm history report <br />Technician Name (print): --74NR /'—,,2,,n Signature: <br />33x2 u r <br />Certification No.: %0�L 5 License. No.: � O ,Ila 1.A, <br />Testing Company Name:I DA- ~' <br />esr Phone No.::J'<w _ D /� <br />Site Address: I "//- 5 <br />_ _ A&I W 0f <br />Date of Testi ng/Servicing: T /C <br />Page I of 3 <br />Monitoring System Certification <br />D. Results of Testing/Servicing <br />03101 <br />
The URL can be used to link to this page
Your browser does not support the video tag.