Laserfiche WebLink
D. Results of Testing/Servicin <br />Software Version Installed: <br />Complete the following checklist: <br />Qa"Yes ❑ No* <br />Is the audible alarm operational? <br />Yes ❑ No* <br />Is the visual alarm operational? <br />❑ No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />Yes ❑ No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br />not interfere with their proper operation? _ <br />❑ Yes ❑ No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />/A <br />operational? <br />es ❑ No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />❑ N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all that apply) ®gu—mp/Trench Sensors; ❑ Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? B -Te -s; ❑ No. <br />❑ Yes ❑ <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />N/A <br />I mechanical overfill prevention. valve is installed), is the overfill warning alarm visible and audible at the tank <br />—fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? % <br />❑ Yes* o <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />Yes* No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />❑ Product; 13Water. If yes, describe causes. in Section E, below. <br />Y 13No* <br />;:Yes <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />❑ No* I <br />Is all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. Comments: <br />