COMPLIANCE INFO_2002-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ACKERMAN
>
1725
>
2300 - Underground Storage Tank Program
>
PR0231309
>
COMPLIANCE INFO_2002-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2022 3:24:31 PM
Creation date
6/23/2020 6:45:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2012
RECORD_ID
PR0231309
PE
2361
FACILITY_ID
FA0003756
FACILITY_NAME
KISHIDA, GEORGE INC
STREET_NUMBER
1725
STREET_NAME
ACKERMAN
STREET_TYPE
DR
City
LODI
Zip
95240
APN
06219001
CURRENT_STATUS
01
SITE_LOCATION
1725 ACKERMAN DR
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231309_1725 ACKERMAN_2002-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11/30/2009 16:31 FAX 2093683234 GEORGE AISHIDA INC 0 006 <br />F. In -Tank Gauging / SIR Equipment: ® Check this box if tank gauging is used only for inventory control. <br />❑ Check this box if no tank gauging or SIR equipment Is installed, <br />This lection must be completed If in -tank gauging equipment Is used to perform iiak detection monitoring. <br />Complete the following checklist. <br />is <br />Yes <br />❑ <br />No' <br />Has all input wiring been inspected for proper entry alid termination, including testing for ground faults? <br />® <br />to <br />Yea <br />Yes <br />❑ <br />❑ <br />No' <br />No' <br />Were all tank gauging probes visually, inspected fore mage and residue buildup? <br />Was accuracy of system product level readings tested? <br />® <br />Yes <br />❑ <br />No" <br />Was accuracy of system water level readings tested?. <br />® <br />Yes <br />❑ <br />No" <br />Were all probes reinstalled property? <br />Yea <br />❑ <br />No' <br />Were all Items on the equipment manufacturer's main enance checklist completed? <br />n Section H, below, describe how and when these deficiencies were or will be corrected, <br />ne Leak Detectors (LLD): ❑ Check this box I� LLDs are not installed. <br />rmmnluta Mn rnlln..,inn nhn kll,t. <br />0 <br />yes <br />❑ <br />No' <br />For equipment start-up or annual equipment cartiflo'ation, was a leak simulated to verify LLD performance? (Check all that apply) <br />❑ <br />NIA <br />Simulated leak rate! ® 3 g.p.h.; ❑ 0.1 g,p,h ; 0 0.2 g. p. h. <br />® <br />Yes <br />0 <br />No` <br />Were all LLDs Confirmed operational and accurate wl in rogulatory requirements? <br />® <br />Yes <br />❑ <br />No, <br />Was the testing apparatus properly calibrated? _ <br />Yes <br />❑ <br />No* <br />For mechanical LLDs, does the LLD restrict product flaw if it detects a leak? <br />El <br />NIA <br />❑ <br />Yes <br />❑ <br />No, <br />For electronic LLDs, does the turbine automatically shlut oft If the LLD detects a leak? <br />® <br />NIA <br />❑ <br />Yes <br />❑ <br />No, <br />For electronic LLDs, does the turbine automatically sh t off If any portion of the monitoring system is disabled or disconnected? <br />® <br />N/A <br />i <br />❑ <br />Yes <br />❑ <br />No* <br />For electronic LLDs, does the turbine automatically shut off If any portion of the monitoring system malfunctions or fails a test? <br />N/A <br />❑ <br />Yes <br />❑ <br />No"For <br />electronic 4LOs, have all accessible wiring connections been visually Inspected? <br />N/A <br />® <br />Yes <br />f <br />No' <br />Were all Items on the equipment manufacturers maintenance checklist completed? <br />I Section H, below, describe how and when these deficiencies were or will be correcTd, <br />1. Comments, <br />Monitoring System Certification Page 3 of 4 l 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.