My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ACKERMAN
>
1725
>
2300 - Underground Storage Tank Program
>
PR0231309
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2022 4:20:10 PM
Creation date
6/23/2020 6:45:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231309
PE
2361
FACILITY_ID
FA0003756
FACILITY_NAME
KISHIDA, GEORGE INC
STREET_NUMBER
1725
STREET_NAME
ACKERMAN
STREET_TYPE
DR
City
LODI
Zip
95240
APN
06219001
CURRENT_STATUS
01
SITE_LOCATION
1725 ACKERMAN DR
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231309_1725 ACKERMAN_2013-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VF UNIFIED PROGRAM CONSOLIDATED FORMW <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN (Page 2 of 2) <br /> VI.UNDER DISPENSER CONTAINMENT(UDQ MONITORING <br /> I. UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD 490.54a <br /> .r�, <br /> ❑ 1.CONTINUOUS ELECTRONIC MONITORING x`1.2.FLOAT AND CHAIN ASSEMBLY ❑ 3.ELECTRONIC STAND-ALONE aso-sae <br /> ❑4.NO DISPENSERS ❑99.OTHER(Specify): <br /> PANEL MANUFACTURER: V 49455 MODEL#: 490.56. <br /> LEAK SENSOR MANUFACTURER: 490-57 1 MODEL#(S): 490.58 <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS <br /> ❑ a.YES �R„b.NO 490.59 <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN ❑ a.YES b.NO 490.60. <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES b.NO 490.61 <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER a.YES ❑b.NO 440.62 <br /> 2.UDC CONSTRUCTION IS W.SINGLE-WALLED 112.DOUBLE-WALLED 490 <br /> IF DOUBLE WALLED: 49044a <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: Q 1.LIQUID Q 2.PRESSURE Q 3.VACUUM <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ❑a.YES ❑b.NO 490-64e <br /> VII.PERIODIC SYSTEM TEEING. <br /> 1. ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED 49045. <br /> E MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED. 23 CCR 2644.1 <br /> EI-2.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. 4i6-" <br /> SPILL BUCKETS ARE TESTED ANNUALLY. 49047 <br /> VIII.R"O"MPING <br /> The following monitoring/maintenance records are kept for this facility: <br /> _*Alarm logs 49048& ❑Visual Inspection Records 490-ab Q Tank integrity testing results 4go-6sc <br /> SIR testing results(and supporting documentation records). 4904sa U Tank gauging results(and supporting documentation records). 490.68e <br /> ATG Testing results(and supporting documentation records).49o4ar Corrosion Protection 60-day logs 49o-as <br /> M-Equipment maintenance and calibration records. 490-6sh <br /> M TRAINING . <br /> J!J+ersonneI with UST monitoring responsibilities are familiar with all of the following documents relevant to their job duties. 490-6% <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILTTy(Check all that apply) <br /> THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required)49o49b <br /> OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)4go-69e <br /> CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 49049d <br /> CALIFORNIA UNDERGROUND STORAGE TANK LAW 490490 <br /> STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION"490.69f <br /> SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS"490494 <br /> OTHER(Specify):M6gh,m(m <br /> This facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the International Code Council(ICC). <br /> e 'Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 days of hire.This <br /> training will include,but is not limited to,the following: <br /> • Operation of the UST systems in a manner consistent with the facility's best management practices <br /> • The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan <br /> The facility employee's role with regard to spills and overfills as specified in the UST Response Plan <br /> A Names of contact person(s)for emergencies and monitoring alarms.490.70 <br /> X. COMMENTSJADDITIONAL.INFORMATION <br /> Provide additional comments here or indicate how manypa es with additional information on specific monitoring procedures are attached to this plan.490.71 <br /> 0 M <br /> XI PERSONNEL RESPONSIBILITIES <br /> The UST Owner/Operator is responsible for ensuring that:I)the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered by <br /> this plan occurs,2)all conditions that indicate a possible release are investigated,and 3)all monitoring records are maintained properly. <br /> The followin on(s)are responsible forperformingthe monitoring and equipment maintenance: <br /> NAME C-1 490-72 TITLE 490-73 <br /> NAME 49o-74 TITLE 490.75 <br /> The Designated Operator shall perform a monthly visual inspection of the facility, provide a report to the owner/operator,and inform the owner/operator of any <br /> conditions that need follow-up action. <br /> XII.OWNEMPERATOR SIGNATURE <br /> CERTIFICATION:I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> APPLICANT SIGNATURE 490.76 DATE: 490.77 <br /> <<( � <br /> APPLICANT NAME(print): 490'78 APPLICANT TITLE: 440'79 <br /> UPCF UST-D(12/2007)3/4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.