Laserfiche WebLink
i <br />SAN dOAQUIN <br />COUNTY <br />*Environmental Health Department <br />III III! • ' • o • a • • • ' • ' ill <br />• • <br />Facility Name: Facility Address: <br />Date: <br />KISHIDA, GEORGE INC 1725 ACKERMAN DR, LODI <br />November 17, 2017 <br />ykn, ha s..y-e t 7 4 $E t rl�iri "F <br />';A�N1l'I�OL�I'TIONS3f r <br />'- <br />:: £, N <br />iIHE .� <br />INOR - Notice to Compl) <br />My <br />L..., xsI -A . .�': .-.-.., a. t: .. a.� $ <br />Item # <br />Remarks <br />319 <br />CCR 2635(b) No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty. <br />The direct -bury spill container on the diesel 3,000 gallon UST system failed when tested. All spill containers shall <br />have a minimum capacity of five gallons and be capable of containing a spill or overfill until it is detected or cleaned <br />up. Immediately discontinue deposition of petroleum into this tank until the component is repaired or replaced by a <br />properly licensed, trained, and certified contractor under permit and inspection of the EHD. If the spill container <br />can't be replaced immediately, there is a possibility that the diesel 3,000 gallon UST system may be red tagged to <br />prevent fuel inputs. <br />This is a repeat violation, Class 11. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by December 17, 2017. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br />THIS FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received by: Date: November 17, 2017 <br />Inspector: <br />Inspector Phone: <br />Printed Name and Title: <br />CESAR RUVALCABA, EH Specialist <br />(209) 953-6213 <br />Kelli Kishida, Secretary <br />FA0003756 PR0231309 SCO01 11/17/2017 <br />EHD 23-01 Rev. 09/22/16 Page 4 of 4 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />