My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BECKMAN
>
351
>
2300 - Underground Storage Tank Program
>
PR0231310
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2022 2:52:45 PM
Creation date
6/23/2020 6:46:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0231310
PE
2361
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
01
SITE_LOCATION
351 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231310_351 N BECKMAN_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
418
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S'WRCB,January 2002 0 0 Page of <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: X Tank Manufacturer ❑Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure X Vacuum ❑Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Gast Vacuum Pump/Vacuum Gauges in Hg. Equipment Resolution: - '/2"x-30 Hg. <br /> 1= Tank#5-A-B Tank# Tank# Tank# <br /> Is Tank Exempt From Testing?' Yes x No Yes No ❑Yes No ❑Yes No <br /> Tank Capacity: 10k <br /> Tank Material: Jacketed Double <br /> Wall Steel <br /> Tank Manufacturer: K&T Steel <br /> Product Stored: Diesel <br /> Wait time between applying 1 Hour <br /> vacuum and starting test: <br /> Test Start Time: 10:05 <br /> Initial Reading(RI): -5 Hg. <br /> Test End Time: 11:05 <br /> Final Reading(RF): -5 Hg. <br /> Test Duration: 1 Hour <br /> Change in Reading(RF-Ri): 0 Hg. <br /> Pass/Fail Threshold or Criteria: No Loss in Hg. <br /> Test Resait Xbass fail,;; Ps ❑Fail` Pass.; C7 Eal Pass. ❑Fail <br /> Was sensor removed for testing? X Yes ❑No ❑NA Yes ❑No ❑NA Yes ❑No ❑NA Yes ❑No ❑NA <br /> Was sensor properly replaced and X Yes ❑No ❑NA Yes ❑No ❑NA Yes ❑No ❑NA Yes ❑No ❑NA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> ' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {California Code of Regulations,Title 23,Section 2637(a)(6)1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.