COMPLIANCE INFO_2010-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BECKMAN
>
351
>
2300 - Underground Storage Tank Program
>
PR0231310
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2022 2:52:45 PM
Creation date
6/23/2020 6:46:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0231310
PE
2361
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
01
SITE_LOCATION
351 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231310_351 N BECKMAN_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
418
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
B1.0 SCOPE: NOTE: Tank upgrades may combine interior lining with <br /> cathodic protection in accordance with 40 CFR Part <br /> Bl.l Chapter B applies only to 40 CFR 280.21(b)(1)(ii) 280.21(b)(3). When using this method, no future tank <br /> which requires that within 10 years and every 5 years inspections are required (Page 32 of EPA's "Must for <br /> thereafter, the lined tank be internally inspected if the tank UST's", September 1988, EPA/530/UST-88/008, Office of <br /> is not cathodically protected. This chapter provides Underground Storage Tanks,Washington,D.C. 20460). <br /> minimum requirements for internal inspection and <br /> assessments of underground steel storage tanks that have <br /> been upgraded by lining and do not have external cathodic B2.0 PERMITS&APPROVALS <br /> protection. The procedures described in this chapter will <br /> meet the Federal Environmental Protection Agency's <br /> on-site work. <br /> Consult local authorities prior to the initiation of any <br /> Underground Storage Tank Technical Requirements of 40 <br /> CFR part 280.21 (b)(1)(ii) for tanks that do not meet the on- <br /> technical requirements of 40 CFR part 280.21(b)(2). <br /> B3.0 CERTIFICATIONS <br /> B3.1 The contractor shall certify to the tank owner that <br /> B1.2 The inspection and assessment procedure specified the contractor's employees performing the work are <br /> in this chapter shall only apply to tanks that have been knowledgeable of all the safety procedures of Chapters A <br /> previously lined. If a cathodic protection system has been of NLPA 631 including sections A2.0 and A5.0 through <br /> installed on a lined tank, no future inspections are A9.0 and confined space entry using form BFI of chapter <br /> required. Tanks that have not been previously lined and B. The employee shall further certify to the owner using <br /> are to be upgraded by lining or cathodic protection in form BF2 that he has performed all work in strict <br /> conjunction with lining shall be inspected and assessed in accordance with Chapter B and all applicable sections of <br /> accordance with Chapter A,section A10.4. Chapter A of this standard. <br /> B4.0 ENTRY AND CLEANING <br /> B1.3 In general, this chapter provides personnel <br /> certification, testing, inspections of existing linings, test B4.1 Tank entry and cleaning personnel shall follow all <br /> equipment, ultrasonic gauging procedure, and tank the procedures and requirements of Chapter A sections <br /> inspection report requirements. Included are future A5.0 through A8.6. <br /> internal inspection methods within 10 years after lining <br /> and every 5 years thereafter to monitoring conditions <br /> which indicate when a cathodic protection system should B5.0 LINING INSPECTION <br /> be added or the tank should be removed from service. <br /> 44 <br />