4
<br /> U.
<br /> , SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
<br /> P ,err `g 1tt}� t �,�t _ 600E Main St. • Stockton,CA 95202-3029 • Phone(209)468-3420
<br /> kea U.. - Donna Heron,R.E.H.S., Director t `443 " ,
<br /> M t A� r. ENVIRONMENTAL HEALTH
<br /> rr a hP 01 t 'rnk ... Y
<br />+`•<- A '°'. r" SAN JOAQUIN COUNTY CERTIFIED UNIFIED PROGRAM AGENCY
<br /> h PERMIT TO OPERATE
<br /> Program Permits ti Permit
<br /> I ', Record ID Number Program Code and Description �1 �f� u - Valid
<br /> PRO513609 PT0009804 2220-SMALL QUANTITY HAZARDOUS WASTE GENERATOR FACILITY 1/1/2010 To 12/31/2010
<br /> Hazardous Waste Generator Program:
<br /> In order to maintain the permit to operate, Hazardous Waste Generators shall comply with California Health and Safety Code, Div.20,Chap.6.5,Art.2-13,
<br /> Sec_25100 et seq,-and Title 22,California Code of Regulations,Chap.20_
<br /> ----
<br /> PR0231310 2 00--VNDERGROUND STORAGE TANK FACILITY + rr*' = e` ;` 1 1/1/2010 To 12/31!2010
<br /> Underground Storage Tank Program: _' x� ;
<br /> k
<br /> California Health and Safety Code,Div.20,Chap.6.7 and Title 23,California Code of Regulations,Chap 16
<br /> -- ---- - - ----- ------------ -- - - - - ------- ------ --- - -- - -----------------------------------------------------
<br /> P/E Tank# Tank Record ID Permit# Capacity Contents Permit Status System Type Leak Detection
<br /> 2362 13 390002313100131013 PT0004724 8,000 PREMIUM UNLEADED Conditional DOUBLE WALLED Continuous Interstitial Monitoring
<br /> 2360 14 390002313100131014 PT0004725 8,000 DIESEL Conditional DOUBLE WALLED Continuous Interstitial Monitoring
<br /> 2360 15 390002313100131015 PT0004726 10,000 REGULAR UNLEADED Conditional DOUBLE WALLED Continuous Interstitial Monitoring
<br /> 2360 16 390002313100131016 PT0004727 10,000 DIESEL Conditional DOUBLE WALLED Continuous Interstitial Monitoring
<br /> 2360 17 390002313100131017 PT0004728 10,000 DIESEL Conditional DOUBLE WALLED Continuous Interstitial Monitoring
<br /> A+,024040 .
<br /> Underground Storage Tank Permit Conditions ow, -4 4 �h .
<br /> :..
<br /> r
<br /> *r 1) The Permit to Operate will become void if Annual Permit Fees and Service Fees are not paid and/or the UST system(s)fails to remain in compliance with these Permit Conditions
<br /> 2) In order to maintain the operating permit,the owner and operator shall comply with the H&S Code,Div.20,Chap.6.7 and 6.75;and CCR,Title 23,Chap.16 and 18,as well as any conditions
<br /> established by San Joaquin County.
<br /> " 3) If the Tank Operator(s)is different from the Tank Owner,or if the Permit to Operate is issued to a person other than the owner or operator of the tank,the Permittee shall ensure that both
<br /> t the Tank Owner and tank Operator receive a copy of the permit.
<br /> -4) Written Monitoring Procedures and an Emergency Response Plan must be approved by the Environmental Health Department(EHD)and are considererd UST Permit Conditions. The approved
<br /> monitoring,response,and plot plans shall be maintained onsite with the permit.
<br /> 5) The Permittee shall comply with the monitoring procedures referenced in this permit.
<br /> •'d `YF`-, � "`+h r'" s H"'�'t, �• is a ,ens = :.
<br /> b.. ^•6) The Permittee shall perform testing and preventive maintenance on all leak detection monitoring equipment annually,or more frequently if specified by the equipment manufacturer,and
<br /> a� provide documentation of such servicing to this office.
<br /> a.!1) In the event of a spill,leak,or other unauthorized release,the Permitee shall comply with the requirements of Title 23 CCR,Chap.16,Art.5,and the approved Emergency Response Plan,
<br /> 8) Written records of all monitoring performed shall be maintained on-site by the operator and be available for inspection for a period of at least three years from the date the monitoring was
<br /> performed.
<br /> f Ey`= 9) The EHD shall be notified of any change in ownership or operation of the UST system within 30 days of such change.--,'Ask� t x1` * ^ 0-
<br /> 10) Upon any change in equipment,design or operation of the UST system(including change in tank contents or usage),the Permit to Operate will be subject to review,modification or
<br /> 'M. revocation.
<br /> h>a,. ' s wt w f'�§krz ,•
<br /> r r 11) Construction,repair and/or removal permits are required from the EHD prior to any change,repair or removal of UST system equipment
<br /> 1
<br /> 1 ,. ]2) The Permittee shall submit an armual report documenting compliance with the UST Permit Conditions within 30 days of the date of the issuance of this pennrt ��w
<br /> 13) This Permit to Operate shall not be considered permission to violate any laws,ordinances or statutes of any other Federal,State or Local agency 44a* i+
<br /> v
<br /> 14) A Con(114ottal.-Permit may be revoked if corrections specified on the inspection report are not completed by the date(s) indicated.
<br />{ PERMITS TO OPERATE are NOT TRANSFERABLE
<br /> and may be SUSPENDED or REVOKED for cause.
<br /> PERMIT(s)Valid only for: VAN DE POL ENTERPRISES INC. ,rotrv - f ,
<br /> ����'��" Tank Owner: THORPE,JIM OIL INC -
<br /> t rf'
<br /> r THIS FORM MUST BE DISPLAYED CONSPICUOUSLY ON THE PREMISES
<br /> y� Regulated Facility: VAN DE POL ENT INC/PACIFIC PRIDE Facility ID FA0003773
<br /> 351 N BECKMAN RDt ,_ m" tF " ; A`44
<br /> ,«/r, Account'D AR0003353
<br /> z Ria " LODI CA 95241 t.., u�diA 1
<br /> " Y ,r�� Issued 2/10/2010
<br /> h � w " Billing Address: ATTN SHACKELFORD, TED
<br /> VAN DE POL ENT INC/PACIFIC PRIDE �r �ik
<br /> g ! n 4 PO BOX 1107
<br /> TyI �F t a1
<br /> STOCKTON ,
<br /> CA 95201 1107
<br /> p,Nw�{�`'Y
<br /> 4 >* ,s5' sF
<br /> � •�'� A ��'' s� ` �� �t*Kr ,. ��pa� 2'1r � �`��`t.:- x3€ � q-� i � ''' z'�'S"' yJs.� .
<br />
|