My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BECKMAN
>
351
>
2300 - Underground Storage Tank Program
>
PR0231310
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2022 4:33:55 PM
Creation date
6/23/2020 6:46:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231310
PE
2361
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
01
SITE_LOCATION
351 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231310_351 N BECKMAN_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
478
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4pRECEIED <br />W <br />4S <br />��, January 2006 <br />' <br />Spill Bucket Testing Report Form AUG 2 <br />This form is intended for use by contractors performing annual testing of UST spill containme t,��il q�s��Ajn#E to and <br />printouts from tests (f applicable), should be provided to the facility owner/operator for s j�� }�i�`�jo'— ry agency- <br />DOOM <br />gency. <br />7FPA <br />Of <br />1 _ FACii.ITV INFORMATION <br />Facility Name: LODI PAC PRIDE Date of Testing: 06-27-17 <br />Facility Address: 351 N BECKMEN RD LODI CA <br />Facility Contact: TED Phone: <br />Date Local Agency Was Notified of Testing :5-17-17 <br />Name of Local Agency Inspector (ifpresent during testing): SAN JOAQUIN CO GARETT <br />2. TESTING CONTRACTOR INFORMATION <br />CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. <br />Technician's Signature: Date:06-27-17 <br />' State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements <br />may be more stringent. <br />Company Name: AFFORDA TEST 4162 n1 Street Galt, CA 95632 (209) 744-0112 Fax: (209) 744-0116 <br />Technician Conducting Test: ❑ Ed Stearns ❑ Zane A. Nimmo ❑ David A. Winkler ® Felix G. Ramirez <br />8184188 5263322 -UT 5263373 -UT 5273934 -UT <br />Credentials': ® ICC Service Tech. ® SWRCB Tank Tester <br />3. SPILL BUCKET TESTING INFORMATION <br />Test Method Used: ® Hydrostatic ❑ Vacuum ❑ Other <br />Test Equipment Used: TAPE / H2O <br />Equipment Resolution: 1/16 <br />Identify Spill Bucket (By <br />Tank Number, Stored <br />Product, etc. <br />1 DIE <br />2 87 <br />3 91 <br />4 RED DIE <br />5 DIE 2 <br />` <br />Bucket Installation Type: <br />❑ Direct Bury <br />® Contained in <br />Sump <br />❑ Direct Bury <br />® Contained in <br />Sump <br />❑ Direct Bury <br />® Contained in <br />Sump <br />❑ Direct Bury <br />® Contained in <br />Sump <br />❑ Direct Bury <br />® Contained in <br />Sum <br />Bucket Diameter: <br />11 <br />11 <br />11 <br />11 <br />11 <br />Bucket Depth: <br />13 <br />13 <br />13 <br />13 <br />13 <br />Wait time between applying <br />vacuum/water and start of <br />test: <br />- <br />- <br />- <br />- <br />- <br />Test Start Time (Ti): <br />1300 <br />1300 <br />1300 <br />1300 <br />1300 <br />Initial Reading (Rj): <br />12 <br />12 <br />12 <br />12 <br />12 <br />Test End Time (TF): <br />1400 <br />1400 <br />1400 <br />1400 <br />1400 <br />Final Reading (RF): <br />12 <br />12 <br />12 <br />12 <br />12 <br />Test Duration (TF — Tj): <br />1 HOUR <br />1 HOUR <br />1 HOUR <br />1 HOUR <br />1 HOUR <br />Change in Reading (RF - <br />Rj): <br />0 <br />0 <br />0 <br />0 <br />0 <br />Pass at Threshold or <br />Criteria: <br />Test IRult; ®Pass ❑ Fad 0 Pass ❑® Pass ❑ Fail j® Pass ❑ Fad' <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. <br />Technician's Signature: Date:06-27-17 <br />' State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements <br />may be more stringent. <br />
The URL can be used to link to this page
Your browser does not support the video tag.