Laserfiche WebLink
TEST DATE: May 2, 1995 <br />CLIENT: UL 3:NC <br />WORK ORDER NUMBER: 964135 <br />SITE: ULTRAMAR 502 <br />Tank ID: <br />2 <br />Bottom to top fill in inches: <br />152.0 <br />Product: <br />PLUS <br />Bottom to grade fill in inches: <br />160.0 <br />Capacity in gallons: <br />10,000 <br />Fill pipe length in inches: <br />57.0 <br />Diameter in inches: <br />95.00 <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: <br />330 <br />Stage I vapor recovery: <br />DUAL <br />Material: <br />DW STEEL <br />Stage II vapor recovery: <br />ASSIST <br />Tank: <br />No <br />Resiliency cc: 170 <br />Water table depth in inches: <br />Manifolded Vent: <br />ICES <br />Determined by (method): <br />MONTR WELL <br />V/R: No <br />E <br />Test method: <br />Alert 1000 <br />New/passed Failed/replaced <br />Psi at tank bottom: <br />1.67 <br />detector detector <br />Fluid level in inches: <br />62.00 <br />Test method: FTA <br />UFT/OFT: <br />UF'r <br />Make: IND JACKET <br />Fluid volume in gallons: <br />6.912 <br />Model: F82 <br />Water level in inches: <br />0.00 <br />S/N: 0126950631 <br />Test time: <br />08:41-11:11 <br />Open time in sec: 3.00 <br />Number of thermisters: <br />0 <br />Holding psi: 15 <br />Spec'Ific gravity: <br />0.748 <br />Resiliency cc: 170 <br />Water table depth in inches: <br />300.00 <br />Test leak rate mg 189.0 <br />Determined by (method): <br />MONTR WELL <br />s: <br />Metering psi: 10 <br />psi: <br />Leak rate in gph: <br />0.009 <br />Calib. leak in gph: 3.00 <br />RESULT: <br />PASS <br />RESULT: PASS <br />Test method: Alert 1050 <br />Test time: 11:35-11:47 <br />Ullage volume: 3,088 <br />Ullage pressure: <br />RESULT: PASS <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 2: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 3: <br />Temperature: <br />Flow rate (cfh): <br />>OMMEM1i'TS <br />i <br />Material: DW FIBERr3 <br />Diameter (in): <br />2.0 <br />Length (ft): <br />80.0 <br />Test psi: <br />50 <br />Bleedback cc: <br />210 <br />Test time (min): <br />30 <br />Test 1: start time: <br />08:54 <br />finish psi: <br />50 <br />vol change cc: <br />3 <br />Test 2: start time: <br />09:04 <br />finish psi: <br />50 <br />vol change cc: <br />0 <br />Test 3: start time: <br />09:14 <br />finish psi: <br />5o <br />vol change cc: <br />0 <br />Final gph: <br />0.002 <br />RESULT: <br />PASS <br />Test type: AcuRite <br />Pump type: PRESSURE Pump make <br />RED JACKET <br />