Laserfiche WebLink
IED PROGRAM CONSOLIDATED FOFO 6_('�_DL <br />TANK <br />UNDERGROUND STORAGE TANKS - TANK PAG �Z'i) oa <br />UNDERGROUND PIPING <br />SYSTEM TYPE ® 1. PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY 458 <br />CONSTRUCTION I ❑ 1. SINGLE WALL ❑ 3. LINED TRENCH ❑ 99. OTHER 460 <br />MANUFACTURER 02. DOUBLE WALL ❑ 95. UNKNOWN <br />MANUFACTURER TelefleX <br />❑ 1. BARE STEEL ❑ 6. FRP COMPATIBLE w/100% METHANOL <br />❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL ❑ UKNOWN <br />❑ 3. PLASTIC COMPATIBLE W/ CONTENTS ❑ 99. OTHER <br />® 4. FIBERGLASS ❑ 8. FLEXIBLE (HDPE) <br />[15. STEEL W/COATING ❑ 9. CATHODIC PROTECTION 464 <br />ABOVEGROUND PIPING <br />❑ 1. PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY 459 <br />❑ 1. SINGLE WALL ❑ 95. UNKNOWN 462 <br />❑ 2. DOUBLE WALL ❑ 99. OTHER <br />461 MANUFACTURER <br />❑ 1. BARE STEEL ❑ 6. FRP COMPATIBLE W/100% METHANOL <br />❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br />❑ 3. PLASTIC COMPATIBLE W/ CONTENTS ❑ 8. FLEXIBLE (HDPE) ❑ 99. OTHER <br />❑ 4. FIBERGLASS ❑ 9. CATHODIC PROTECTION <br />❑ 5. STEEL W/COATING ❑ 95. UNKNOWN <br />SINGLE WALL PIPING 466 <br />PRESSURIZED PIPING (Check all thatapply): <br />❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR <br />LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION -AUDIBLE AND VISUAL <br />ALARMS. <br />❑ 2. MONTHLY 0.2 GPH TEST <br />[13. ANNUAL INTEGRITY TEST (0.1 GPH) <br />CONVENTIONAL SUCTION SYSTEMS <br />[15. DAILY VISUAL MONITORING OF PUMPING SYSTEM +TRIENNIAL PIPING INTEGRITY <br />TEST (0.1 GPH) <br />SAFE SUCTION SYSTEMS (NO VALUES IN BELOW GROUNDPIPING): <br />[17. SELF MONITORING <br />GRAVITY FLOW <br />❑ 9. BIENNIAL INTEGRITY TEST (0.1 GPH) <br />SECONDARILY CONTAINED PIPING <br />PRESSURIZED PIPING (Check all that apply): <br />10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND <br />(Check one) <br />❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br />❑ b. AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM <br />DISCONNECTION <br />0c. NO AUTO PUMP SHUT OFF <br />® 11. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITH FLOW SHUTOFF OR <br />RESTRICTION <br />® 12. ANNUAL INTEGRITY TEST (0.1 GPH) <br />SUCTION/GRAVITY SYSTEM <br />❑ 13. CONTINUOUS SUMP SENSOR +AUDIBLE AND VISUAL ALARMS <br />EMERGENCY GENERATORS ONLY (Check all that apply) <br />❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF +AUDIBLE AND <br />VISUAL ALARMS <br />❑ 15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITHOUT FLOW SHUT OFF OR <br />RESTRICTION <br />❑ 16. ANNUAL INTEGRITY TEST (0.1 GPH) <br />[117. DAILY VISUAL CHECK <br />463 <br />465 <br />ABOVEGROUND PIPING <br />SINGLE WALL PIPING 467 <br />PRESSURIZED PIPING (Check all that apply): <br />❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR <br />LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION + AUDIBLE AND VISUAL <br />ALARMS. <br />❑ 2. MONTHLY 0.2 GPH TEST <br />❑ 3. ANNUAL INTEGRITY TEST (0.1GPH) <br />❑ 4. DAILY VISUAL CHECK <br />CONVENTIONAL SUCTION SYSTEMS (Check all that apply) <br />[15. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br />E16. TRIENNIAL INTEGRITY TEST (0.1 GPH) <br />SAFE SUCTION SYSTEMS (NO VALVES IN BELOW GROUND PIPING): <br />❑ 7. SELF MONITORING <br />GRAVITY FLOW (Check all that apply): <br />[18. DAILY VISUAL MONITORING <br />❑ 9. BIENNIAL INTEGRITY TEST (0.1 GPH) <br />SECONDARILY CONTAINED PIPING <br />PRESSURIZED PIPING (Check all that apply): <br />10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND <br />(Check one) <br />❑ a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br />❑ b AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM <br />DISCONNECTION <br />❑c NO AUTO PUMP SHUT OFF <br />❑ 11. AUTOMATIC LEAK DETECTOR <br />❑ 12. ANNUAL INTEGRITY TEST (0.1 GPH) <br />SUCTION/GRAVITY SYSTEM <br />013. CONTINUOUS SUMP SENSOR+ AUDIBLE AND VISUAL ALARMS <br />EMERGENCY GENERATORS ONLY (Check all that apply) <br />❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF +AUDIBLE AND <br />VISUAL ALARMS <br />❑ 15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) <br />❑ 16. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 17. DAILY VISUAL CHECK <br />UPCF (1/99 revised) Formerly SWRCB Form B <br />