Laserfiche WebLink
T 3:SUPER <br />PRODUCT CODE 3 <br />THERMAL COEFF :.000700 <br />TANK DIAMETER 95.00 <br />TANK PROFILE I PT <br />FULL VOL 10058 <br />FLOAT SIZE: 4.0 IN. <br />WATER WARNING <br />1.5 <br />HIGH WATER LIMIT: <br />2.5 <br />MAX OR LABEL VOL: <br />10050 <br />OVERFILL LIMIT <br />90% <br />9052 <br />HIGH PRODUCT <br />95% <br />9555 <br />DELIVERY LIMIT <br />10% <br />1005 <br />LOW PRODUCT <br />400 <br />LEAK ALARM�'LIMIT: <br />99 <br />SUDDEN LOSS LIMIT: <br />99 <br />TANK TILT <br />0.00 <br />PROBE OFFSET <br />0.00 <br />MANIFOLDED TANKS <br />TO: NONE <br />LEAK MIN PERIODIC: 10% <br />1005 <br />PERIODIC TEST TYPE <br />STANDARD <br />LIQUID SFNSOR SETUP <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />L 1:SUPER <br />SUMP <br />GROSS TEST FAIL <br />TRI-STATE <br />(SINGLE FLOAT) <br />ALARM DISABLED <br />CATEGORY <br />: STP SUMP <br />PER TEST AVERAGING: OFF <br />L '2' :REGULAR SUMP <br />TANK TEST NOTIFY: OFF <br />TRI-STATE <br />(SINGLE FLOAT) <br />CATEGORY <br />: STP SUMP <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY 5 MIN <br />L 3:PLUS SUMP <br />PUMP THRESHOLD 10-00% <br />TRI-STATE <br />(SINGLE FLOAT) <br />CATEGORY <br />: STP SUMP <br />L 4:SUPER <br />ANNULAR <br />TRI-STATE <br />(SINGLE FLOAT) <br />CATEGORY <br />: ANNULAR SPACE <br />L 5:REGULAR ANNULAR <br />TRI-STATE <br />(SINGLE FLOAT) <br />CATEGORY : <br />ANNULAR SPACE <br />LEAK TEST METHOD <br />- - - - - - <br />-- - - - - - <br />TEST ON DATE : ALL TANK <br />JUN 18, 2002 <br />L G:PLUS ANNULAR <br />START TIME : DISABLED <br />TRI-STATE <br />(SINGLE FLOAT) <br />TEST RATE :0.20 GAL/HR <br />CATEGORY : <br />ANNULAR SPACE <br />DURATION : 5 HOURS <br />TST EARLY STOP:DISABLED <br />LEAK TEST REPORT FORMAT <br />ENHANCED <br />E <br />c <br />OUTPUT' RELAY SETUP <br />R I:SUPER TURBINE <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />LIQUID SENSOR ALMS <br />L I:FUEL ALARM <br />L I:SENSOR OUT ALARM <br />L I:SHORT ALARM <br />ALARM HISTORY REPORT <br />SYSTEM ALARM <br />PAPER OUT <br />SEP 25. 2008 3:42 AM <br />PRINTER ERROR <br />SEP 25, 2008 3:42 AN <br />BATTERY IS OFF <br />JAN 1, 1996 8:00 AM <br />SYS SECURITY WARNING <br />AUG 15, 2008 8:20 AM <br />x x x x X END X x x x x <br />R 2:REGULAR TURBINE <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />LIQUID SENSOR ALMS <br />L 2:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />L 2:SHORT ALARM <br />R a:PLUS TURBINE <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />LIQUID SENSOR ALMS <br />L -J:FUEL ALARM <br />L 3:SENSOR OUT ALARM <br />L 3:SHORT ALARM <br />