Laserfiche WebLink
lb <br />RECONCILIATION SETUP <br />LIQUID SENSOR SETUP <br />AUTOMATIC. DAILY CLOSING <br />TIME: 2:00 AM <br />L 1:SUPER SUMP <br />TRI-STATE (SINGLE FLOAT) <br />PERIODIC RECONCILIATION <br />CATEGORY : STP SUMP <br />MODE: MONTHLY <br />TEMP COMPENSATION <br />T 3:SUPER 3 <br />PRODUCT CODE <br />L 2:REGULAR SUMP' <br />STANDARD <br />THERMAL COEFF :.000700 <br />TRI-STATE (SINGLE FLOAT) <br />BUS SLOT FUEL METER TANK <br />TANK DIAMETER 95.00 <br />1 PT <br />CATEGORY' STP SUMP <br />TANK PROFILE <br />TANK MAP EMPTY - - - - - <br />FULL VOL 10058 <br />L 3:PLUS SUMP <br />TRI-STATE (SINGLE FLOAT) <br />FLOAT SIZE: 4.0 IN. <br />CATEGORY : STP SUMP <br />WATER WARNING : 1.5 <br />HIGH WATER LIMIT: 2.5 <br />L 4:SUPER ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />MAX OR LABEL VOL: 10058 <br />CATEGORY ANNULAR SPACE <br />OVERFILL LIMIT 90% <br />9 <br />HIGH PRODUCT 950 <br />9555 <br />L 5:REGULAR ANNULAR <br />DELIVERY LIMIT 1004 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />T 2:PLUS <br />1005 <br />PRODUCT CODE 2 <br />THERMAL COEFF :.000700 <br />LOW PRODUCT 400 <br />TANK DIAMETER 95.00 <br />1 PT <br />LEAK ALARM LIMIT: 99 <br />LOSS LIMIT: 99 <br />ANNULAR <br />L -STATE <br />TANK PROFILE <br />FULL VOL : 10058 <br />SUDDEN <br />TANK TILT 0.00 <br />TRI (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />PROBE OFFSET 0.00 <br />FLOAT SIZE: 4.0 IN. <br />MAtVIFOLDELi TANKS <br />WATER WARNING 1.5 <br />T#: NONE <br />HIGH WATER LIMIT: 2.5 <br />MAX OR LABEL VOL: 10058 <br />LEAK MIN PERIODIC: 10% <br />1005 <br />OVERFILL LIMIT 90% <br />9052 <br />PERIODIC TEST TYPE <br />HIGH PRODUCT 95% <br />STANDARD <br />9555 <br />DELIVERY LIMIT 12% <br />1 <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />OUTPUT RELAY SETUP <br />LOW PRODUCT : 1000 <br />LEAK ALARM LIMIT: 99 <br />GROSS TEST FAIL <br />ALARM DISABLED <br />- - - - - <br />R 1:SUPER TURBINE <br />SUDDEN LOSS LIMIT: 99 <br />TANK TILT 0.00 <br />PER TEST AVERAGING: OFF <br />TYPE: <br />STANDARD <br />PROBE OFFSET 0.00 <br />TANK TEST NOTIFY: OFF <br />NORMALLY CLOSED <br />MANIFOLDED TANKS <br />TNK TST SIPHON BREAKOFF <br />LIQUID SENSOR ALMS <br />TO: NONE <br />DELIVERY DELAY 5 MIN <br />L 1:FUEL ALARM <br />L 1:SENSOR OUT ALARM <br />PUMP THRESHOLD 10.00% <br />L I:SHORT ALARM <br />LEAK MIN PERIODIC: <br />1209 <br />2:REGULAR TURBINE <br />PERIODIC TEST TYPE <br />TYPE: <br />TYPE: <br />STANDARD <br />STANDARD <br />NORMALLY CLOSED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />LIQUID SENSOR ALMS <br />GROSS TEST FAIL <br />ALARM DISABLED <br />L 2:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />PER TEST AVERAGING: OFF <br />L 2:SHORT ALARM <br />LEAK TEST METHOD <br />R 3:PLUS TURBINE <br />TANK TEST NOTIFY: OFF <br />TEST ON DATE : ALL TANK <br />TYPE: <br />TNK TST SIPHON BREAKOFF <br />JUN 18, 2002 <br />DISABLED <br />STANDARD <br />NORMALLY CLOSED <br />START TIME : <br />DELIVERY DELAY 5 MIN <br />TEST RATE :0.20 GAL/HR <br />PUMP THRESHOLD : 10.00% <br />DURATION : 5 HOURS <br />LIQUID SENSOR ALMS <br />TST EARL',' STOP:LrISABLED <br />ARM <br />L 3:SENS0RLOUT ALARM <br />LEAK TEST REPORT FORMAT <br />L 3:SHORT ALARM <br />ENHANCED <br />