ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0231320
PE
2361
FACILITY_ID
FA0003602
FACILITY_NAME
TESORO (SPEEDWAY) 68151
STREET_NUMBER
35
Direction
N
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04318003
CURRENT_STATUS
01
SITE_LOCATION
35 N CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231320_35 N CHEROKEE_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
453
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C <br />.Albk- %.p <br />IED PROGRAM CONSOLIDATED FO <br />UNDERGROUND STORAGE TANK <br />OPERATING PERMIT APPLICATION - TANK INFORMATION (One form per UST) <br />TYPE OF ACTION (Check one item only. For a UST closure or removal, complete only this section and Sections I, A III, IV, and IX below) 430. <br />❑ 1. NEW PERMIT ❑ 3. RENEWAL PERMIT ® 5. CHANGE OF INFORMATION <br />❑ 6. TEMPORARY UST CLOSURE ❑ 7. UST PERMANENT CLOSURE ON SITE ❑ 8. UST REMOVAL <br />DATE UST PERMANENTLY CLOSED: 430.. <br />1 DATE EXISTING UST DISCOVERED: 430b. <br />I. FACILITY INFORMATION <br />FACILITY ID # (Agency Use Only) - <br />_ ` -17 Er 1 <br />BUSINESS NAME (Same as ility Name or DBA - Doing Business As) 3. <br />esoro/ he1168151 <br />SINESS SITE 103. <br />CITY 104. <br />35 N. Cherokee Lane <br />Lodi <br />II. TANK DESCRIPTION <br />ANK ID # 432. <br />TANK MANUFACTURER 433. <br />TANK CONFIGURATION: THIS TANK IS 434. <br />Trusco <br />® 1. A STAND-ALONE TANK Complete one page for each <br />❑ 2. ONE INA COMPARTMENTED UNIT compartment in the unit. <br />DATE UST SYSTEM INSTALLED 435. <br />TANK CAPACITY IN GALLONS 436. <br />NUMBER OF COMPARTMENTS IN THE UNIT 437, <br />1995 <br />10,000 <br />III. TANK USE AND CONTENTS <br />TANK USE ® la. MOTOR VEHICLE FUELING ❑ ]b. MARINA FUELING ❑ lc. AVIATION FUELING 439. <br />❑ 3. CHEMICAL PRODUCT STORAGE ❑ 4. HAZARDOUS WASTE (Includes Used Oil) ❑ 5. EMERGENCY GENERATOR FUEL [HSC §25281.5(c)] <br />❑ 6. OTHER GENERATOR FUEL ❑ 95. UNKNOWN[199. OTHER (Specify): 439a. <br />............ ............................................................... .... ............... <br />.................................................................... ............. .... ........ .......... -.................................................. .................................. -................................................................ .............-.............................. ............................................................... <br />CONTENTS PETROLEUM: ❑ la. REGULAR UNLEADED ❑ la MIDGRADE UNLEADED ® 1b. PREMIUM UNLEADED 44°. <br />❑ 3. DIESEL ❑ 5. JET FUEL ❑ 6. AVIATION GAS <br />❑ 8. PETROLEUM BLEND FUEL ❑ 9. OTHER PETROLEUM (Specify): 440a. <br />............ ...................... <br />....................... .........................................................................._..................................................................................................................................................................................................................................... <br />NON -PETROLEUM: ❑ 7. USED OIL ❑ 10. ETHANOL <br />❑ 11. OTHER NON -PETROLEUM (Specify): 440b. <br />IV. TANK CONSTRUCTION <br />TYPE OF TANK❑ 1. SINGLE WALL ® 2. DOUBLE WALL ❑ 95. UNKNOWN 443. <br />..........................................................................................................................................................................-................................................................................................................................................................................................................. <br />PRIMARY CONTAINMENT ® 1. STEEL ❑ 3. FIBERGLASS ❑ 6. INTERNAL BLADDER 444. <br />❑ 7. STEEL + INTERNAL LINING ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): 444x. <br />_..................................................................................................... <br />............................................................-......................................................................................................................................................................................................................._..................... ........................... <br />SECONDARY CONTAINMENT ❑ 1. STEEL [13. FIBERGLASS ❑ 6. EXTERIOR MEMBRANE LINER ® 7. JACKETED 445. <br />❑ 90. NONE ❑ 95. UNKNOWN [199. OTHER (Specify): 445a. <br />...... ..................................... <br />............................. ............... .............................................................................................. ...................-................ ............................................... .............................._......_.............._ <br />OVERFILL PREVENTION ❑ 1. AUDIBLE & VISUAL ALARMS ❑ 2. BALL FLOAT ® 3. FILL TUBE SHUT-OFF VALVE 452. <br />❑ 4. TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br />V. PRODUCT I WASTE PIPING CONSTRUCTION <br />PIPING CONSTRUCTION El 1. SINGLE WALL ® 2. DOUBLE WALL 1:199. OTHER 460. <br />-............................................................................. <br />....................................... ...................... ......................................_................................................................ -............ ..................................................................... ............. ................................ _............................ ................................................................................... <br />SYSTEM TYPE ® I. PRESSURE ❑ 2. GRAVITY 0 3 CONVENTIONAL SUCTION El 4. SAFE SUCTION [23 CCR §2636(a)(3)] 458 <br />............ <br />PRIMARY LSTEEL ® 4. FIBERGLASS ❑ 8. FLEXIBLE ❑ 10. RIGID PLASTIC 464. <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): 464a. <br />...................................................... <br />.................................................................................................................................................................................................................................... <br />SECONDARY CONTAINMENT ❑ 1. STEEL ® 4. FIBERGLASS ❑ 8. FLEXIBLE ❑ 10. RIGID PLASTIC 464b. <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): 464c. <br />......... ................. ... ................................._............ ......... _.................... ...................................._....................................................................................._.................._........................................ <br />URBINE CONTAINMENT SUMP TYPE ® 1. SINGLE WALL ❑ 2. DOUBLE WALL ❑ 90. NONE 464d. <br />PIPIG/T. <br />N <br />VI. VENT, VAPOR RECOVERY (VR) AND RISER / FILL PIPE PIPING CONSTRUCTION <br />VENT PRIMARY CONTAINMENT ® 1. STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify): 464el. <br />......................................................................................................................................................................................................................................................... <br />VENT SECONDARY CONTAINMENT ❑ 1. STEEL ❑ 4. FIBERGLASS El 10. RIGID PLASTIC ® 90. NONE El 99. OTHER (Specify): 464171. <br />........................................... ........................................... ..................................... ................ .... .................................. ..................................................................................... ................. _.............................................. ............. ............................................... ............................................ ................................. .................. .........4......... <br />g. <br />VR PRIMARY CONTAINMENT ❑ L STEEL ® 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify): q4� I <br />g...:..... <br />................................................................................................................................................................................................................................................................................................................................................................................................................... <br />.................................................................................. <br />h. <br />VR SECONDARY CONTAINMENT ❑ 1. STEEL ® 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify): 464h1. <br />_... _..... _..._................................................................................................................................................................................................................................................................................................................................................................................. <br />.................................................................. I............................. <br />VENT PIPING TRANSITION SUMP TYPE ❑ 1. SINGLE WALL ❑ 2. DOUBLE WALL ® 90. NONE 4641. <br />....................................................................................................................................................................................................................................................--........................................................................................................................ <br />RISER PRIMARY CONTAINMENT ® 1. STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify): 4644] <br />..........1.......... <br />..........................................................................................................................................................................._._...............................................................................................................................................................................................................................................................................-................................... <br />RISER SECONDARY CONTAINMENT ❑ 1. STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ® 90. NONE ❑ 99. OTHER (Specify): 464k1. <br />..................................................................................................................................................._..............................................................................._......._......................................................................................................................................................................................._.............................._........... ...................... <br />FILL COMPONENTS INSTALLED ® L SPILL BUCKET ® 3. STRIKER PLATE/BOTTOM PROTECTOR ❑ 4. CONTAINMENT SUMP 451 a -c. <br />VII. UNDER DISPENSER CONTAINMENT (UDC) <br />CONSTRUCTION TYPE ® 1. SINGLE WALL ❑ 2. DOUBLE WALL ❑ 3. NO DISPENSERS ❑ 90. NONE 469a. <br />................... <br />................. ................................ ......................................................_........................................................................................................................................................................................................................................ _...............................................................-................................................................................................................................................... <br />CONSTRUCTION MATERIAL ® 1. STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 99. OTHER (Specify)4696. <br />469c. <br />VIII. CORROSION PROTECTION <br />STEEL COMPONENT PROTECTION ❑ 2. SACRIFICIAL ANODE(S) ❑ 4. IMPRESSED CURRENT ® 6. ISOLATION 448, <br />IX. APPLICANT SIGNATURE <br />CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true, <br />accurate, and in full compliance with legal requirements. <br />APPLICANT SIGNATURE , <br />DATE 1/7/2011 470 <br />APPLICANT NAME (print) Sandy Edikards 471. <br />APPLICANT TITLE Environmental Compliance 472. <br />UPCF UST -13 Rev. (12/2007) - 1/2 www.unidocs.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.