My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
35
>
2300 - Underground Storage Tank Program
>
PR0231320
>
COMPLIANCE INFO_2009-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2022 2:49:25 PM
Creation date
6/23/2020 6:46:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0231320
PE
2361
FACILITY_ID
FA0003602
FACILITY_NAME
TESORO (SPEEDWAY) 68151
STREET_NUMBER
35
Direction
N
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04318003
CURRENT_STATUS
01
SITE_LOCATION
35 N CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231320_35 N CHEROKEE_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
453
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IED PROGRAM CONSOLIDATED FOAW <br />UNDERGROUND STORAGE TANK <br />OPERATING PERMIT APPLICATION - TANK INFORMATION (one form per UST) <br />TYPE OF ACTION (Check one item only. For a UST closure or removal, complete only this section and Sections 1, II, 111, IV, and IX below) 430. <br />❑ L NEW PERMIT ❑ 3. RENEWAL PERMIT ® 5. CHANGE OF INFORMATION <br />❑ 6. TEMPORARY UST CLOSURE ❑ 7. UST PERMANENT CLOSURE ON SITE ❑ 8. UST REMOVAL <br />DATE UST PERMANENTLY CLOSED: 430.. 1 DATE EXISTING UST DISCOVERED: 4306, <br />L FACILITY INFORMATION <br />FACILITY ID # (Agency Use Only) <br />1. <br />BUSINESS NAME (Same as Facility Name or DBA - Doing Business As) 3. <br />USA/Tesoro 68151 <br />BUSINESS SITE ADDRESS 103. <br />CITY 104. <br />35 N. Cherokee Lane <br />Lodi <br />II. TANK DESCRIPTION <br />TANK ID # 432. <br />TANK MANUFACTURER 433, <br />TANK CONFIGURATION: THIS TANK IS 434. <br />j <br />TTUSCO <br />® 1. A STAND-ALONE TANK Complete one page for each <br />❑ 2. ONE IN A COMPARTMENTED UNIT compartment m the unit. <br />DATE UST SYSTEM INSTALLED 435. <br />TANK CAPACITY IN GALLONS 436. <br />NUMBER OF COMPARTMENTS IN THE UNIT 437, <br />1995 <br />12,000 <br />IIL TANK USE AND CONTENTS <br />TANK USE ® la. MOTOR VEHICLE FUELING ❑ lb. MARINA FUELING ❑ Ic. AVIATION FUELING 439. <br />❑ 3. CHEMICAL PRODUCT STORAGE ❑ 4. HAZARDOUS WASTE (Includes Used Oil) ❑ 5. EMERGENCY GENERATOR FUEL [HSC §25281.5(c)] <br />❑ 6. OTHER GENERATOR FUEL ❑ 95. UNKNOWN ❑ 99. OTHER (Specify) 439a. <br />.......... <br />.. ............ .................. ............. ..................................................... ........... ............. .......... .............. <br />CONTENTS PETROLEUM: ® la. REGULAR UNLEADED ❑ lc MIDGRADE UNLEADED ❑ lb. PREMIUM UNLEADED 440 <br />❑ 3. DIESEL ❑ 5. JET FUEL ❑ 6. AVIATION GAS <br />❑ 8. PETROLEUM BLEND FUEL ❑ 9 OTHER PETROLEUM (Specify)_ 440.a <br />. <br />....... <br />NON -PETROLEUM: ❑ 7. USED OIL ❑ 10. ETHANOL <br />❑ 11. OTHER NON -PETROLEUM (Specify): 4406. <br />IV. `'TANK CONSTRUCTION <br />TYPE OF TANK ❑ 1 SINGLE WALL ® 2 DOUBLE WALL ❑ 95 UNKNOWN 443' <br />.. ....... . ............. ................ ...... ....... .......... <br />............ 44a <br />PRIMARY CONTAINMENT ® 1. STEEL ❑ 3. FIBERGLASS ❑ 6. INTERNAL BLADDER <br />4aa <br />❑ 7. STEEL + INTERNAL LINING El 95. UNKNOWN El 99. OTHER (Specify): a . <br />SECONDARY CONTAINMENT ❑ 1. STEEL ❑ 3. FIBERGLASS ❑ 6. EXTERIOR MEMBRANE LINER ® 7. JACKETED 445. <br />445a. <br />❑ 90. NONE❑ 95. UNKNOWN ❑ 99. OTHER(Specify): <br />..................................................._.._.._.....__.........................._.........._.__._..........r... <br />......................_..__.................._........_........................................... .____.__ <br />_. <br />OVERFILL PREVENTION ❑ 1. AUDIBLE & VISUAL ALARMS ❑ 2. BALL FLOAT ® 3. FILL TUBE SHUT-OFF VALVE 452. <br />❑ 4. TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br />V. PRODUCT I WASTE PIPING CONSTRUCTION <br />PIPING CONSTRUCTION ❑ 1. SINGLE WALL ® 2. DOUBLE WALL [1 99. OTHER 460. <br />.................................................................. . <br />SYSTEM TYPE ® 1. PRESSUREO._2. GRAVITY ❑ 3. CONVENTIONAL SUCTION ❑ 4. SAFE SUCTION [23 CCR §2636(a)(3)] 458. <br />......................... <br />PRIMARY CONTAINMENT El 1. STEEL ® 4. FIBERGLASS ❑ 8. FLEXIBLE ❑ 10. RIGID PLASTIC 464. <br />❑ 90. NONEUNKNOWN OTHER (Specify).:..._. 464a. <br />...... ... ........... ..............._..._._.......❑.._95 ..._........._._....❑..._99 <br />SECONDARY CONTAINMENT ❑ 1. STEEL ® 4. FIBERGLASS ❑ 8. FLEXIBLE ❑ 10. RIGID PLASTIC 4646. <br />❑ 90. NONE 95. UNKNOWN OTHER (Specify):..._. a64c. <br />................................ ... ........ ................................. ............_0 .......................0..._99:.. <br />PIPING/TURBINE CONTAINMENT SUMP TYPE ® 1. SINGLE WALL ❑ 2. DOUBLE WALL ❑ 90. NONE 464x. <br />VI. VENT, VAPOR RECOVERY (VR) AND RISER / FILL PIPE PIPING CONSTRUCTION <br />VENT PRIMARY CONTAINMENT ® 1. STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify): 464e]. <br />.... ........... .......... ................. ._....... <br />VENT SECONDARY CONTAINMENT ❑ 1. STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ® 90. NONE ❑ 99. OTHER (Specify): 464n <br />.......... <br />..............................................................................................................................................................................................................................................................._....................................__..................................................................................-......... ......................................................................... <br />4648. <br />VR PRIMARY CONTAINMENT ❑ 1. STEEL ® 4. FIBERGLASS [110. RIGID PLASTIC [190. NONE [1 99. (Specify): 46481, <br />................. .................... .............. <br />VR SECONDARY CONTAINMENT ❑ 1. STEEL ® 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify): 464h1. <br />.............................................................................................................................................................................................................................................................................................................................................................................................................. ...................................................................................... 4......;....... <br />VENT PIPING TRANSITION SUMP TYPE ❑ 1. SINGLE WALL ® 2. DOUBLE WALL ❑ 90. NONE 64` <br />.......... .. .................... - .. .......................... .......... ...... ............. ... ........... .............. .. ......... <br />RISER PRIMARY CONTAINMENT ® 1. STEEL ❑ 4. FIBERGLASS ❑ 10 RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify). 4644] <br />.... <br />............... ... .............................. .............. ........ ..... .......... .................. .-........ ..................... .................. ........... .................. ........... .......... <br />46441...... <br />RISER SECONDARY CONTAINMENT ❑ 1. STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ® 90. NONE ❑ 99. OTHER (Specify): 4644. <br />....... <br />...................... ................ .................. <br />FILL COMPONENTS INSTALLED ® 1. SPILL BUCKET ® 3. STRIKER PLATE/BOTTOM PROTECTOR ❑ 4. CONTAINMENT SUMP 45la-c <br />VII. UNDER DISPENSER CONTAINMENT (UDC) <br />CONSTRUCTION TYPE ® 1. SINGLE WALL ❑ 2. DOUBLE WALL ❑ 3 NO DISPENSERS ❑ 90. NONE 469a. <br />........................................................................................................-........................................................................................................................................_._............................................................................................ ......... <br />CONSTRUCTION MATERIAL ® 1. STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 99. OTHER (Specify) 4696. <br />VIII. CORROSION PROTECTION <br />STEEL COMPONENT PROTECTION ❑ 2. SACRIFICIAL ANODE(S) ❑ 4. IMPRESSED CURRENT ❑ 6. ISOLATION 448, <br />IX. APPLICANT SIGNATURE <br />CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true, <br />accurate, and in full compliance with legal requirements. <br />APPLICANT SIGNATURE S <br />DATE 2/2/2009 470 <br />APPLICANT NAME (print) Sandy Ed ards 471 <br />APPLICANT TITLE Environmental Compliance 472. <br />UPCF UST -B Rev. (12/2007) - 1/2 www.unidoes.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.