My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
35
>
2300 - Underground Storage Tank Program
>
PR0231320
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2022 2:57:25 PM
Creation date
6/23/2020 6:46:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0231320
PE
2361
FACILITY_ID
FA0003602
FACILITY_NAME
TESORO (SPEEDWAY) 68151
STREET_NUMBER
35
Direction
N
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04318003
CURRENT_STATUS
01
SITE_LOCATION
35 N CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231320_35 N CHEROKEE_2016-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
120
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />• <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.ora/ehd <br />. . <br />Facility Name: Facility Address: Date: <br />TESORO (SHELL) 68151 35 N CHEROKEE LN, LODI January 26, 2016 <br />Item # Remarks <br />201 <br />CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br />Maintenance and monitoring records for the last three years were not found on site. The daily alarm logs for <br />January and February 2015 were incomplete. These records shall be maintained on site for at least three years. <br />Monitoring records include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and <br />maintenance records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in the <br />field; (5) logs of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; <br />(6) results of inventory readings and reconciliations. Immediately locate and maintain all maintenance and <br />monitoring records for the last three years on site and submit copies to the EHD. <br />This is a minor violation. <br />207 <br />CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to document all the alarms from the attached alarm history on the November 6, 2015 <br />designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br />missing alarms include: T1 (87 product) overfill alarms on October 14 and October 24, 2015. During the monthly <br />inspection, the designated operator shall review the alarm history for the previous month, check that each alarm <br />was documented and responded to appropriately, and attach a copy of the alarm history with documentation taken <br />in response to any alarms to the monthly report. Ensure that designated operators performing monthly inspections <br />at this facility are including all of the required information on the reports. <br />This is a minor violation. <br />209 <br />CCR 2715(f) Designated operator employee training not performed or log not kept. <br />The designated operator employee training for all employees was not found listing employee name, hire date, and <br />training date. The designated operator shall train facility employees for which he or she is responsible in the proper <br />operation and maintenance of the UST system once every 12 months. The training shall include, but is not limited <br />to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br />the training records to the EHD. <br />This is a minor violation. <br />Overall Inspection Comments: <br />On site on January 26, 2016, to conduct a routine UST monitoring system certification, spill container, and line <br />leak detector inspection. A Return to Compliance Certification form and inspection report were left at the site at <br />the time of the inspection. Jennifer Rodriguez gave permission to perform the inspection, take photos and <br />collect samples, if needed. <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />Received ynspector: <br />one: <br />ate: <br />(initial): A.0. <br />VICKI MCCARTNEY, Senior REHS <br />1 (209) 468-9852 <br />01/26/2016 <br />Page 4 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.