San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> CJaderground Storage Tank Program,Cnspection Report <br /> Facility Name: Facility Address: Date: <br /> TESORO(SHELL)68151 35 N CHEROKEE LN, LODI January 26, 2017 <br /> UST System.0111s6tvations` <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑V ❑R ❑COS <br /> 324 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ❑V ❑R ❑COS <br /> Single-Walled Non-Pressurized Piping . <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> Other violations <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R ❑COS <br /> `SUMMARY OF VIOLATIONS <br /> (CLASS',I GLASS Il,.or MINOR=Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> The tank information form for the diesel tank lists that functioning vapor recovery pipe is present. Diesel tanks do <br /> not have vapor recovery piping since it is used for gasoline tanks only. The facility employee updated CERS and <br /> removed the vapor recovery piping listing during the inspection. Violation resolved. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Routine and Monitoring System Certification UST inspection. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: January 26, 2017 Inspector: Inspector Phone: <br /> Printed Name and Title: GARRETT BACKUS, Lead Senior REHS (209)468-2986 <br /> Angela Ocampo,Cashier <br /> FA0003602 PR0231320 SCO01 01/26/2017 <br /> EHD 23-01 Rev.09/22/16 Page 3 Of 3 Underground Storage Tank Program OR <br />