My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1987-2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
15
>
2300 - Underground Storage Tank Program
>
PR0231404
>
COMPLIANCE INFO_1987-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/16/2024 2:37:28 PM
Creation date
6/23/2020 6:46:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-2002
RECORD_ID
PR0231404
PE
2361
FACILITY_ID
FA0002915
FACILITY_NAME
TRACY MARKET INC
STREET_NUMBER
15
Direction
E
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21435004
CURRENT_STATUS
01
SITE_LOCATION
15 E GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231404_15 E GRANT LINE_1987-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
355
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i•� <br /> o\ V,�M 3 �� <br /> IFIED PROGRAM CONSOLIDATED FO 3 / /O� <br /> Y/ TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 <br /> (two pages per tank) <br /> Pape_of_ <br /> TYPE OF ACTION ❑1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason-for local use only) (Specify reason-for local use orgy) ❑ 8 TANK REMOVED 430 <br /> FACILITY ID: 1 <br /> BUS ESS NAME(Same as FACILITY NAME or DBA-Doing As) 3 ® r <br /> 7 r1 ?3i2C� ea"' [/x <br /> LOCATION WITHIN SITE(Optional) 431 <br /> I.TANK DENIM6"Caledplclt plan,Witlt tho location of It*UST system inciu*Q buildings end landrnarks ahaY bt <br /> a <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK Yes _No 434 <br /> 39"2 3 140/0 140 4 I&MOZAJU_. 'LbIAJ6- If*Yes',complete ane papa for each cornpartme t <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 3 /! -c 000 <br /> ADDITIONAL DE CRIPTION(For local use only) 438 <br /> IL TANK CONTENT: <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> 016. MOTOR VEHICLE FUEL [31a. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (If marked compete Petroleum Type) Alb. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION FUEL <br /> ❑2. NON-FUEL PETROLEUM ❑1c. MIDGRADE UNLEADED ❑4. GASOHOL [199.OTHER <br /> ❑3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materiels Inventory page) 441 CAS#(from Hazardous Materials Inventory page) 442 <br /> ❑4. HAZARDOUS WASTE <br /> (Incudes Used Oil) Q �p <br /> ❑95. UNKNOWN ' //IUL+� fJ n'V Ccs r C� <br /> IN. TANK CONSTRUC71ON <br /> TYPE OF TANK 1. SN'^LF WALL 3.SING!.E WALL WITH 5. SINGLE�,VAL L WITH IN's•I?NAI BLADDER SYSTE.':' T!2 <br /> ll.i.e_... l� iThl•+ rr.1C,'!t�9a:Ma33k ANE I.INEk j 0f,, L" -%74 <br /> X2. DOUBLE WALL ❑4. SIGNLE WALL IN VAULT ❑99. OTHER <br /> TANK MATERIAL-pnmary tank 1. BARE STEEL [13.-FIBERGLASS/PLASTIC 0 5. CONCRETE 95. UNKNOWN 444 <br /> (Check one item only) ❑2. STAINLESS STEEL ;q 4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE W/ ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) 100%METHANOL <br /> TANK MATERIAL-second;Ytank 1. BARE STEEL 03. FIBERGLASS/PLASTIC 5. CONCRETE C1 95. UNKNOWN 445 <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4.STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) W/100%METHANOL <br /> ❑5. CONCRETE [110.COATED STEEL <br /> TANK INTERIOR LINING [11.RUBBER LINED ❑3.EPDXY LINING (,5.GLASS LINING [195.UNKNOWN 446 DATE INSTALLEL 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ❑6 UNLINED ❑99 OTHER <br /> I (Check one item only) (For local use only) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC[]3 FIBERGLASS REINFORCED PLASTIC 795 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION ❑4 IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED ! 452 <br /> (Check all 1K1 SPILL CONTAINMENT /�O+ <br /> j that apply) ❑1 ALARM ❑3 FILL TUBE SHUT OFF VALVE <br /> 192 DROP TUBE ,�y 092 BALL FLOAT C34 EXEMPT <br /> 3 STRIKER PLATE cis a <br /> IV.TANK LEAK DETECTION(A description of the morittoring program shall be sutamitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that appy) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> [31 VISUAL(EXPOSED PORTION ONLY (Check one item only) <br /> ❑5 MANUAL TANK GAUGING(MTG) ❑1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE UK2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> +(SIR) BIENNIAL TANK TESTING ❑99 OTHER <br /> IV.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YRJMO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> REMAINING <br /> gallons ❑Yes ❑ No <br /> UPCF (1/99 revised) 0 Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.