My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
15
>
2300 - Underground Storage Tank Program
>
PR0231404
>
COMPLIANCE INFO_2003-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2021 1:21:27 PM
Creation date
6/23/2020 6:46:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2004
RECORD_ID
PR0231404
PE
2361
FACILITY_ID
FA0002915
FACILITY_NAME
TRACY MARKET INC
STREET_NUMBER
15
Direction
E
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21435004
CURRENT_STATUS
01
SITE_LOCATION
15 E GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231404_15 E GRANT LINE_2003-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
363
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' L IFIED PROGRAM CONSOLIDATED FO4(tb103 - <br /> (0� <br /> TANKS 0l �1,,)d3 <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 ` <br /> (Two pages per tank) <br /> Page_of <br /> TYPE OF ACTION ❑ I.NEW PERMIT ff4.AMENDED PERMIT [15.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Check one kern only) ❑ 3.RENEWAL PERMIT G Q u►PT- mob - ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specify reason) (Specify reason) ❑ 8.TANK REMOVED <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3. FACILITY ID: 1. <br /> 014FP.2E MAaV fiT 3 <br /> LOCATION WITHIN SITE(Optional) 431. <br /> I.TANK DESCRIPTION <br /> (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK Ill i4 ��,© jL Vq b- 43z. TANK MANUFACTURER 433• COMPARTMENTALIZED TANK ❑Yes No 434. <br /> 3 M G fl I~fL AI W F_fr If"Yes,"complete one page for each compartment. <br /> DATE INSTALLED 435• TANK CAPACITY IN GALLONS 436• NUMBER OF COMPARTMENTS 437 <br /> (YEAR/MO) V 9(L f Z,, Q 0 0 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> II.TANK CONTENTS <br /> TANK USE 439. PETROLEUM TYPE 440. <br /> 10 I. MOTOR VEHICLE FUEL la. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (Ifchecked.complete Petroleum Type) ❑lb. PREMIUM UNLEADED [13. DIESEL ❑6. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑Ic. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT 441• CAS# from Hazardous Materials Inventory page 442. <br /> COMMON NAME (from Hazardous Materials Inventory page) ( ry P g <br /> ❑ 4. HAZARDOUS WASTE <br /> (Includes U,cd Oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK [11. SINGLE WALL ❑3. SINGLE WALL WITH EXTERIOR ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SINGLE WALL IN A VAULT 99. OTHER <br /> TANK M:\TERIAL-primary tank ®I. BARE STEEL ❑3. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95.UNKNOWN 444. <br /> (Cheek one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTIC(FRP) W/100%METHANOL <br /> TANK MATERIAL-secondary tank ❑1. BARE STEEL 3. FIBERGLASS/PLASTIC ❑8. FRP COMPTIBLE W/100%METHANOL [195.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL®4. STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑ I.RUBBER LINED 3.EPDXY LINING Ll 5.GLASS LINING ❑95.UNKNOWN 446. DATE INSTALLED 447. <br /> OR COATING ❑2.ALKYD LINING ❑4.PHENOLIC LINING ®6.UNLINED ❑99.OTHER <br /> (Check one item only) <br /> OTHER CORROSION ❑I.MANUFACTURED CATHODIC 3.FIBERGLASS REINFORCED PLASTIC ❑95.UNKNOWN 448. DATE INSTALLED 449, <br /> PROTECTION PROTECTION ❑4.IMPRESSED CURRENT [:199.OTHER <br /> (If A licable) ❑2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED 450. TYPE 451. OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED , 452. <br /> (Check all that apply) ®I.SPILL CONTAINMENT ❑1.ALARM _ ®3.FILL TUBE SHUT OFF VALVE 93 <br /> ®2.DROP TUBE '0 3 ❑2.BALL FLOAT ❑4.EXEMPT <br /> ®3.STRIKER PLATE t!fIJL <br /> IV.TANK LEAK DETECTION <br /> (A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453• IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check all that apply) (Check one item only) <br /> ❑ 1. VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) [] I.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> [12. AU"FONIATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE 2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3. CONTINUOUS ATG ❑7.GROUNDWATER ❑3.MANUAL MONITORING <br /> ❑4. STATISTICAL INVENTORY RECONCILIATION [18.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING ❑99.OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455. ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456. TANK FILLED WITH INERT MATERIAL? 457. <br /> gallons ❑Yes ❑ No <br /> UPCF h\+fwrc-b(1/99)-1/4 http://www.unidocs.org Rev.02/16/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.