Laserfiche WebLink
WRITTEN PROCEDURES <br />FOR MONITORING <br />NOUBLE CONTAINMENT UNDERGROUND STORAGE TANK SYSTE <br />Quik Stop Market #138 <br />1153 Lincoln Blvd. <br />Tracy, California 95376 <br />The gasoline storage and dispensing system at this location consists of two (2) 10,000 -gallon and <br />one (1) 8,000 -gallon double-wall fiberglass, dry -interstitial, underground storage tanks serving <br />two (2) double -sided multi -product dispensers (MPDs). Product lines are double-wall fiberglass. <br />A. Each tank and product line is monitored continuously by probes within the tank annular <br />space and turbine sump, respectively. Float and chain assemblies in dispenser pans will <br />trip shear valves in the event that dispensers leak. <br />B. The Gilbarco EMC Tank and Line Monitoring System is manufactured by Veeder-Root. <br />Leak conditions trigger visual and audible alarms located on the monitoring system <br />control panel. Turbine shutdown will occur if either power is lost to the control <br />panel or sump probes sense line leak conditions. <br />C. The monitor control panel is located in the market office. The monitor is placed in test <br />mode daily to check alarm function. Results are recorded on a "Daily Monitoring System <br />Inspection Log". <br />D. Monitoring is the responsibility of Pargat & Jaswinder Litt, Franchisees, or their <br />designated duty clerk. Maintenance of the monitoring equipment is the responsibility of <br />Quik Stop Markets, Inc. Mike Karvelot, Director of Environmental Affairs, will <br />authorize all repairs. <br />E. If an alarm occurs, the Franchisee will immediately contact the Quik Stop Gasoline <br />Department, which will in turn dispatch a qualified service contractor to the site. The <br />service contractor will determine the cause of alarm and advise Quik Stop of site <br />conditions. If an unauthorized release to secondary containment has occurred, action will <br />be immediately taken to implement the Simplified Response Plan. <br />F. The monitor panel and probes are checked and certified annually in August. Preventive <br />maintenance and spill bucket is scheduled annually in conjunction with monitor certification. <br />SB -989 testing is conducted triennually in December ('04, '07, ad infinitum). <br />G. A description of the gasoline system operation and operator's responsibilities are included <br />in the Franchise Agreement. Initial training in operation of the tank system and <br />monitoring equipment is conducted "on the job" under the supervision of Quik Stop <br />personnel and the Designated UST Operator. <br />