COMPLIANCE INFO_2012-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
1153
>
2300 - Underground Storage Tank Program
>
PR0231413
>
COMPLIANCE INFO_2012-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 2:19:25 PM
Creation date
6/23/2020 6:47:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2016
RECORD_ID
PR0231413
PE
2361
FACILITY_ID
FA0003122
FACILITY_NAME
QUIK STOP MARKET #3138
STREET_NUMBER
1153
STREET_NAME
LINCOLN
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
231-190-12
CURRENT_STATUS
01
SITE_LOCATION
1153 LINCOLN BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231413_1153 LINCOLN_2012-2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
402
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITCRING SYSTEM CERTIFI ACCEIVED <br /> MAKE/MODEL OF MONITORING SYSTEM: Veeder-Root L <br /> CERTIFICATION/TEST DATE: Au ust 20, 2014 <br /> Al. U 111' <br /> FACILITY A2. OWNER <br /> Name Quik Stop Market#138 Name Quik Stop Markets Inc nn''^^//����nn���p� HEALT <br /> Address 1153 Lincoln Blvd.,Tracy,CA 95376 Address 4567 Enterpri;aQb rtt`6h'It,`C'A'914538 <br /> Phone# 510-657-8500 Phone# 510-657-8500 DEPARTMENT <br /> Contact Roger Batra Contact Debbie Markovich <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering,Inc. <br /> Address 1868 E.Hazelton Avenue,Stockton,CA 95202 Address P.O.Box 1025,W.Sacramento,CA 95691 <br /> Notified August 06,2014 Lic# 617238 A,B,Haz <br /> Inspector Stacy Rivera Contact Dulcinea Coven <br /> Phone# 209-468-8257 Phone# 916-373-1166 <br /> B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (check the appropriate boxes to Indicate equipment Inspected/serviced) <br /> B7: TANKS <br /> Tank#1 (Product): Gasoline-87 Tank#2 (Product): Gasoline-89 <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ■ Annular Space or Vault Sensor Model: 0794390-409 ■ Annular Space or Vault Sensor Model: 0794390-409 <br /> ■ Piping Sump/Trench Sensor(s) Model: 0794360-206 ■ Piping Sump/Trench Sensor(s) Model: 0794380-206 <br /> ❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s) Model: <br /> ■ Mechanical Line Leak Detector Model: VMI 99LD-2000 ■ Mechanical Line Leak Detector Model: VMI 99LD-2000 <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment In Section E) Model: <br /> Tank#3 (Product): Gasoline-91 Tank#4 (Product): <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ■ Annular Space or Vault Sensor Model: 0794390-409 ❑ Annular Space or Vault Sensor Model: <br /> ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 ❑ Piping Sump/Trench Sensor(s) Model: <br /> ❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s) Model: <br /> ■ Mechanical Line Leak Detector Model: VMI 99LD-2000 ❑ Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> B2: DISPENSERS/UDC's <br /> Dispenser#: 1-2 Dispenser#: 3-4 <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ■ Shear Valves ■ Shear Valves <br /> ■ Dispenser Containment Float(s)and Chain(s) ■ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser#: Dispenser#: <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chaln(s) ❑ Dispenser Containment Float(s)and Chains) <br /> Dispenser#: Dispenser# <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> C. CERTIFICATION I certify that the equipment Identified In this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this Certification Is Information(e.g.manufacturers'checklists)necessary to verity that this Information Is correct and a Plot Plan showing th <br /> layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply <br /> II ■ System set-up ■ Alarm History Report <br /> ` "" W e WALTON <br /> Signature: 01� <br /> ENGINEERING,INC. <br /> Technician/Cert#: Jessie Wadkins/B35391 5307886-UT Date: August 20,2014 <br /> 2014 Walton Engineering,Inc. <br />