COMPLIANCE INFO_2017-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
1153
>
2300 - Underground Storage Tank Program
>
PR0231413
>
COMPLIANCE INFO_2017-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/16/2022 4:40:01 PM
Creation date
6/23/2020 6:47:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017-2018
RECORD_ID
PR0231413
PE
2361
FACILITY_ID
FA0003122
FACILITY_NAME
QUIK STOP MARKET #3138
STREET_NUMBER
1153
STREET_NAME
LINCOLN
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
231-190-12
CURRENT_STATUS
01
SITE_LOCATION
1153 LINCOLN BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231413_1153 LINCOLN_2017-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N,J O A Q U I N Environmental Health Department <br /> COUNTY- <br /> �.. .3kNf .�'�..R4.u �'�'e.,., 'h'M"'Z.a: §r��. .v t.�'....,... �� '�t'$ .ww .♦ S.` .. .. 4� ...� u... �� ci-��- <br /> 55 <br /> Facility Name: Facility Address: Date: <br /> QUIK STOP MARKET#3138 1153 LINCOLN BLVD, TRACY August 07, 2018 <br /> if <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years ❑V D R ❑COS <br /> 203 CCR 2712(b) Failure to maintain records of repairs,lining,and upgrades on site,for the life of the UST D V ❑R D COS <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site ❑V ❑R ❑COS <br /> 205 CCR 2712(i),2634(e) Failure to submit a current UST Response Plan and have it available onsite ❑V ❑R ❑COS <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions D V ❑R D COS <br /> 207 HSC 25294 Failed to record unauthorized release from primary containment ❑V ❑R ❑COS <br /> 208 CCR 2650(e),2652 Failed to notify the EHD of a reportable unauthorized release ❑V ❑R ❑COS <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed ■V ■R ❑COS <br /> 210 CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months ❑V ❑R ❑COS <br /> 211 CCR 2715(f)(2) Designated operator employee training not performed or log not kept ■V ■R ❑COS <br /> 212 CCR 2715(f)(2) Unstaffed facility failed to have or implement a training program approved by the EHD ❑V D R ❑COS <br /> 213 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept ❑V ❑R D COS <br /> 214 HSC 25281.5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept ❑V ❑R ❑COS <br /> 215 CCR 2712(i) Failure to retain a copy of the permit to operate at the facility ❑V ❑R ❑COS <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills ❑V ❑R ❑COS <br /> 302 HSC 25291(b) UST system incapable of detecting leak from primary into secondary containment(pre-Jul 2003) ❑V ❑R ❑COS <br /> 303 HSC 25290.2(d) Monitoring system not maintained to detect entry into secondary containment(Jul 2003-Jun 2004) ❑V ❑R ❑COS <br /> 304 HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2004) D V ❑R ❑COS <br /> 305 HSC 25290.1(e) VPH monitoring of the interstitial spaces of the UST system is not maintained ❑V ❑R D COS <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity ❑V D R ❑COS <br /> 307 CCR 2631(g),2632(c) Monitoring system of the interstitial space of a double walled system not maintained ❑V ❑R ❑COS <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm ■V ■R ■COS <br /> 309 CCR 2636(f)(1) Monitoring in sump/UDC failed to activate an audible and visual alarm or stop the flow product ❑V D R ■COS <br /> 310 CCR 2636(f)(5) Failure to meet monitoring requirements in lieu of annual line tightness test ❑V ❑R ❑COS <br /> 311 CCR 2638(a),2641() Failed to properly program or operate leak detection equipment ❑V D R ❑COS <br /> 312 CCR 2638(f),2641(i) Failed to affix a tag sticker on monitoring equipment certified,repaired,or replaced ❑V ❑R ❑COS <br /> 313 HSC 25290.1,25290.2, Failure to construct,operate,and maintain primary containment as product-tight ❑V ❑R D COS <br /> 25291 <br /> 314 HSC 25290.1,25290.2, Failed to have secondary containment or secondary containment not tight ❑V ❑R D COS <br /> 25291 <br /> 315 HSC 25291(e) Water in secondary containment not removed,analyzed,and properly disposed of(pre-Jul 2003) ■V ■R ❑COS <br /> 316 HSC 25290.1(c3), Secondary containment not constructed to prevent water intrusion(after Jul 2003) D V ❑R ❑COS <br /> 125290.2(c3) <br /> 317 CCR 2636(f)(2) Line leak detector not installed ❑V ❑R D COS <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi ■V ■R ■COS <br /> FA0003122 PR0231413 SCO01 08/07/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 2 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.