Laserfiche WebLink
Z 5400 ALDRIN CT. <br />groundwater resources inc. BAKERSFIELD, CALIFORNIA 93313 <br />General Engineering Contractor <br />Class All-laz License No. 520768 <br />RE: CONTEL <br />430 W. Center Street <br />Manteca, California 95336 <br />The following is in response to your request for an explanatior-4 <br />of the tank test failure dated March 13, 1989. 11 <br />The test was made with the Petro-Tite testing system which <br />includes circulating the product inside the tank while under <br />pressure to stabilize the product temperature. During this <br />procedure, the tank will expand due to the process involved. <br />At the time the test was made it was unknown that the tank was a <br />double walled tank (the annular space access points were <br />covered). Petro -rite stated that their system will not work on <br />double walled tanks due to the continuous expansion on the tank <br />ends. <br />After uncovering the tank, it was found to be a double walled <br />tank® At that time, GRI contacted Precision Industries in <br />Stockton, California to re -test the tank with the Horner System. <br />The tank passed using this system. <br />The results to this test are enclosed as requested. If you ha <br />any further questions or requests, please call (805) 835-7700. 1 <br />Sincerely, <br />Pat M. Young <br />MAILING ADDRESS: P.O. BOX 9383, BAKERSFIELD, CA 93389 (805) 835-7700 <br />LOS ANGELES (213) 724-3147 <br />September 15, 1989 <br />Mr. Jaime Favilla <br />San Joaquin County <br />E;7, `AENE II 1 <br />"AX <br />Local Health District <br />Post Office 2009 <br />Stockton, California 95201 <br />RE: CONTEL <br />430 W. Center Street <br />Manteca, California 95336 <br />The following is in response to your request for an explanatior-4 <br />of the tank test failure dated March 13, 1989. 11 <br />The test was made with the Petro-Tite testing system which <br />includes circulating the product inside the tank while under <br />pressure to stabilize the product temperature. During this <br />procedure, the tank will expand due to the process involved. <br />At the time the test was made it was unknown that the tank was a <br />double walled tank (the annular space access points were <br />covered). Petro -rite stated that their system will not work on <br />double walled tanks due to the continuous expansion on the tank <br />ends. <br />After uncovering the tank, it was found to be a double walled <br />tank® At that time, GRI contacted Precision Industries in <br />Stockton, California to re -test the tank with the Horner System. <br />The tank passed using this system. <br />The results to this test are enclosed as requested. If you ha <br />any further questions or requests, please call (805) 835-7700. 1 <br />Sincerely, <br />Pat M. Young <br />MAILING ADDRESS: P.O. BOX 9383, BAKERSFIELD, CA 93389 (805) 835-7700 <br />LOS ANGELES (213) 724-3147 <br />