Laserfiche WebLink
301 -0333 -XXX <br />Line pressure probe <br />9 Interfaces with present EMS 3000 <br />Safe for all Class 1, Division 1, Group D <br />hazardous locations <br />*Leak Rate Delectability: <br />Catastrophic leaks of more than 10 <br />gallons per hour within 15 seconds <br />Leaks of 3 gallons per hour within <br />5 minutes (maximum) <br />Leaks of .05 gallons per hour in as <br />little as 30 minutes* <br />*Confidence Factors: <br />95% leak detection <br />5% false alarms <br />*Pressures: <br />Continuous: 0 to 30 psi <br />Maximum: 60 psi <br />• Operating Temeratures: -401 to +50° C <br />• Range of Product Temp Sensed: -15'to+35C <br />*Resets: <br />Push button switch on top of probe <br />This increases awareness of potential <br />leaks <br />*Alarms: <br />Provides LEAK alarm through EMS 3000 <br />(visual and audible) when leak rates <br />are exceeded <br />*Remote Capability: <br />May be programmed through an EMS 3000 <br />relay to provide remote notification of alarm <br />status <br />*Relay Connections: <br />Through EMS 3000 allowing you to shut down <br />pumps or other equipment in the event a <br />LEAK alarm is activated <br />*Mounting: <br />Mounts on a 2 inch NPT fined "T"' <br />Requires 8 inches clearance to top of <br />access way <br />913ody: <br />Made of tough stainless steel and anodized <br />aluminum <br />*Dimensions: <br />Height: 7.5 inches, Width: 6.0 inches, <br />Weight: 4.6 pounds <br />* Variations in line temperature and in-line air <br />volume may increase detection time. <br />Application Notes: <br />Probe is mounted on a 2 inches NPT fitted "T' <br />(not supplied) as close to the pump as possible., <br />Leak tests are conducted every time the pump <br />shuts off. This frequent testing rate is <br />designed to insure any catastrophic leak is <br />immediately seen. This provides valuable <br />monitoring for even busy stational The <br />longer the pump is off, the more detailed the <br />leak test and the smaller the detectable leak. <br />The Tidel Line Pressure probe has been <br />designed to meet or exceed the known state, <br />county, and federal line leak detection <br />requirements. Our probe has been designed to <br />give the operator a wide range of line pressure <br />detection coverage, but at the same time, <br />attention has been given to the needs of the <br />petroleum dispensing business. We've <br />designed our probe to have great flexibility! <br />Stainless Steel <br />Cap/Anodized <br />Aluminum Bass <br />8 inches <br />Head clearar <br />Required <br />i <br />2 inch NPT <br />Reset Button 30 inch Cable 301.0334 -XXX <br />I - - <br />a — 6 intim <br />2615 E. Belt Line Rd. <br />Carrollton, Tx. 75006 <br />(214) 416-8222 <br />ENGINEERING,INQ FAX# (214) 416-8324 <br />1.800-678-7577 <br />IM 3 744M <br />