My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1987-1998
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_1987-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/18/2022 1:58:10 PM
Creation date
6/23/2020 6:47:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-1998
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_1987-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
387
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Delivery History <br />Delivery History is the first section found in the History <br />Report. This section contains up to the Last Ten Deliveries <br />received. It shows for each delivery: date; time; gross and <br />net gallonage; and initial/ending product levels. <br />The ATG Probe Alarm/Warning History section <br />immediately follows the Delivery History section on the <br />History Report. This section includes the time and date of <br />the last three alarm or warning occurrences for each of the <br />conditions below: <br />• Low Product Level - Warning <br />• High Product Level - Alarm <br />• Water Detection - Warning <br />• Theft Detection - Alarm <br />• Failed ATG Leak Tests - Alarm <br />• Probe Failure - Alarm <br />External Probe <br />(EdMS-3000 Only) <br />The External Probe Alarm History section immediately <br />follows the ATG Probe Alarm/Warning on the History <br />Report. This section includes the date and time of the last <br />three alarm occurrences (by probe number). <br />I ' I . I I ' ' .WA.I i I-111 <br />i 11 Only) <br />AndHistory Reports <br />ERROR.................This message is printed if the EMS -3000 <br />detects a malfunction in the probe. <br />ALARM -OIL........ This message is printed if the presence of <br />hydrocarbons are detected or as an alarm <br />status condition. In the case of a line pressure <br />probe, an oil alarm indicates a failed 3 gallon <br />per hour test. <br />ALARM -WET ...... This message is printed if the presence of <br />water is detected. In the case of a line <br />pressure probe, a wet alarm indicates a failed <br />,2 gallon per hour test. <br />ALARM -DRY ...... This message is printed if no liquids or <br />hydrocarbons are detected in a normally wet <br />environment. (Example: groundwater <br />monitoring well probe.) <br />ATG Leak ' History <br />The ATG Leak Test History section immediately follows <br />the External Probe Alarm section on the History Report. <br />This section reflects the results of the last three leak tests <br />performed utilizing the ATG probes. It includes: the date <br />and time the leak test was started and ended; the method in <br />which the test was terminated; and the result of the leak <br />test. (For more information on Leak Test, see Section <br />3-0 ATG Leak Test Mode.) <br />Theft Mode History <br />The Theft Mode History section immediately follows the <br />Leak Test History section on the History Report If a theft <br />or thefts have been detected, this section of the History <br />Report will indicate up to the last three occurrences. For <br />each theft detected, the report will show: start time and <br />date; end time and date; beginning product level in inches; <br />ending product level in inches; beginning and ending <br />product volumes in gallons or liters; time and date theft <br />detected; and number of gallons or liters lost during the <br />theft. (For more information on Theft Tests, see <br />Section 5-0 Theft Mode.) <br />HistorySelf Test <br />The Self Test History -section immediately follows the Theft <br />Mode History section on the History Report. The self test <br />program enables the user to perform: Display Test; <br />Memory Test; LED Test; Beeper Test; Audible Alarm Test; <br />Relay Test; ATG Probe Test; and External Probe Test. This <br />section of the History Report will show the time and date of — <br />the last test (if self test has been performed) and the results <br />of each test. Additionally, a Self Test Report can be <br />generated by pressing the Self Test Button on the keypad <br />while the keyswitch is in the normal position. (See Section <br />3-3, Figure 3a). <br />
The URL can be used to link to this page
Your browser does not support the video tag.