My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1987-1998
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_1987-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/18/2022 1:58:10 PM
Creation date
6/23/2020 6:47:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-1998
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_1987-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
387
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Automatic Tank Gau•- <br />Alarm And WarningCause/Action- <br />U111 111 <br />AIaT Condition causc Action Reauired <br />High Product Fuel level has risen above the preset IF TANK FILLING IS IN PROGRESS, CEASE <br />threshold IMMEDIATELY, AS TANK MAY BECOME <br />OVER -FILLED. Once the product level falls below <br />this threshold, the alarm will be automatically clemd <br />Leak Console has failed a leak test If a leak is suspected, See Section 4.0 To Disable The <br />ATG Leak Test Mode From The Keypad on pages 13 <br />and 14. Note that the Leak Test Disable Report will be <br />printed. The leak test results will appear at the bottom of <br />the report (See Figure 6, page 14). Additional testing <br />may be required, such as tightness testing, etc..., to verify <br />that the tank is actually leaking <br />NOTE: Tanks should not be exhumed soley on the <br />basis of leak test information. <br />Theft Detection Unauthorized product removal from INVESTIGATE CAUSE OF ALARM AND REPORT <br />the storage tank TO THE PROPER AUTHORITIES <br />Probe Failure EMS Console has recognized a NOTIFY TIDEL SERVICE DEPARTMENT <br />problem with the Automatic Tank IMMEDIATELY AT 1-800-678.7577 FOR LOCAL <br />Gauge probe SERVICE DISPATCH <br />Water Detection <br />Water has been detected in the tank <br />Stick the tank using water finderpaste (using "Kolor" water <br />above the preset threshold <br />finder or equivalent) to verify water is present in the tank. <br />If water is present in the tank, then it may be desireable to <br />have it pumped out. If no water is present, contact the EMS <br />Service Department. Once the alarm condition has been <br />corrected, the alarm will be automatically cleared <br />Low Product Level <br />Product level in the tank has dropped <br />WARNING WILL CLEAR ITSELF, AS SOON AS <br />below the preset threshold <br />THE PRODUCT LEVEL IS RAISED ABOVE THE <br />PRESET THRESHOLD <br />Automatic Leak Test <br />EMS console has not been sucessful <br />PROVIDE ADEQUATE "QUIET TIME" (NO <br />(ALT) <br />in running a leak test during the <br />DISPENSING ORDELIVERIES/1.6HOURS)PRIOR <br />month/year <br />TO THE END OF THE MONTH OR YEAR TO <br />ALLOW THE CONSOLE TO RUN AND PASS A <br />TEST <br />Line Pressure Probe <br />EMS console has not been successful <br />PROVIDE ADEQUATE "QUIET TIME" (NO <br />Leak Test Reminder <br />in running a I gph leak test on the <br />DISPENSING) FOR UP TO b HOURS PRIOR TO <br />(EMS -3000 Only) <br />product lines during the month <br />THE END OF THE MONTH TO ALLOW THE <br />CONSOLE TO RUN AND PASS A TEST <br />NOTE: POWER MUST BE LEFT ON TO THE <br />SUBMERSIBLE PUMP IN ORDER TO COMPLETE <br />A TEST <br />
The URL can be used to link to this page
Your browser does not support the video tag.