COMPLIANCE INFO_1999-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_1999-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/23/2024 1:10:52 PM
Creation date
6/23/2020 6:47:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2011
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_1999-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
513
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Program Permit Permit <br />Record ID Number Program Code and Description Valid <br />PR0521715 PT0014672 2220 - SMALL QUANTITY HAZARDOUS WASTE GENERATOR FACILITY 1/1/2011 To 12/31/2011 <br />Hazardous Waste Generator Program: <br />In order to maintain the permit to operate, Hazardous Waste Generators shall comply with California Health and Safety Code, Div. 20, Chap. 6.5, Art. 2-13,' <br />Sec. 25100 et seq,_ and Title 22, California Code of Req_ulations, Chap. 20_ <br />---- ------ - - ---- -- --- - ----------------------------------- <br />PR0231425 2300 - UNDERGROUND STORAGE TANK FACILITY 1/1/2011 To 12/31/2011, ' <br />r Underground Storage Tank Program: , <br />C California Health and Safety Code, Div. 20, Chap._ 6.7 and Title 23, California Code of Reulations, Chap 16 <br />------------------------------------------------- -- ----- ---- ------- <br />P/E Tank # Tank Record ID Permit # Capacity Contents Permit Status System Type Leak Detection <br />2362 2 390002314250508163 PT0009601 6,000 DIESEL Active, billable DOUBLE WALLED Continuous Interstitial Monitoring <br />:. DOE ID#: 44017 - t <br />Underground Storage Tank Permit Conditions <br />tj The Permit to Operate will become void if Annual Permit Fees and Service Fees are not paid and/or the UST system(s) fails to remain in compliance with these Permit Conditions <br />2j in order to maintain the operating permit, the owner and operator shall comply with the H&S Code, Div. 20, Chap. 6.7 and 6.75; and CCR, Title 23, Chap. 16 and 18, as well as any conditions y <br />established by San Joaquin County. <br />3) If the Tank Operator(s) is different from the Tank Owner, or if the Permit to Operate is issued to a person other than the owner or operator of the tank, the Permittee -shall ensure that both ;-i <br />the Tank Owner and tank Operator receive a copy of the permit. <br />• .4) Written Monitoring Procedures and an Emergency Response Plan must be approved by the Environmental Health Department (EHD) and are p9."4e pro UST Permit Conditions. The approved <br />monitoring, response, and plot plans shall be maintained onsite with the permit, <br />5) The Permittee shall comply with the monitoring procedures referenced in this permit. <br />b) The Permittee shall perform testing and preventive maintenance on all leak detection monitoring'equipment annually, or more$equently ifspeeOlOed by;the equipment manufacturer, and <br />provide documentation of such servicing to this office. <br />7) In the event of a spill, leak, or other unauthorized release, the Permitee shall comply with the requirements of Title 23 CCR, Chap. 16 ArL S;gdthe approved Emergency Response Plan. <br />"8) Written records of all monitoring performed shall be maintained on-site by the operator and be available for inspection for a period of at least three,years from the date the monitoring was .; <br />A: <br />performed. <br />The EHD shall be notified of any change in ownership or operation of the UST system within 30 days of sucli change. <br />101 Upon any change in equipment, design or operation of the UST system (including change in tank contents or usage) the =rate <br />will be sutsect to review, modification or,revocation.Constmction, repair and/or removal permits are required from the EHD prior to any change, repair or removal of UST system1pt <br />-12) . The Permittee shall submit an amoral report documenting compliance with the UST Pennit Conditions within 30 days of Ute date of the issuance of this permit. <br />13 This Permit to Operate shall not be considered permission to violate any laws, ordinances or statutes of any other Federal, State or Local agency. <br />14) A "Conditional" Permit may be revoked if corrections specified on the inspection report are not completed by the date(s) indicated a: <br />— <br />---------- <br />r--} <br />Y, >. r d� a <br />y kx <br />Al <br />p <br />t'tKivn I kS) valla only Tor: <br />ren A, <br />
The URL can be used to link to this page
Your browser does not support the video tag.