PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_2012-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
530
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
„i V E <br /> AUG 2 9 2017 <br /> Item#214 <br /> X15(4EN AL HEALTH <br /> HSC 25281.5(b)(3) Unburied emergency generator fuel piping not visually insp a m1t <br /> log kept. DEPT i <br /> A log of monthly checks of the unburied single walled piping was not found on site. According to the <br /> designated operator(DO)on site, a company comes out to inspect the generator. The DO did not have the <br /> documents. For an emergency generator tank system,the unburied piping is exempt from regulation if <br /> visual inspections are made each time the system is operated, but no less than monthly, and a log is <br /> maintained. Immediately submit the inspection log to the EHD. <br /> This is a minor violation <br /> RESPONSE: Generator run log was not available at the time of the inspection. Emailed copy <br /> from Richard Silveira shows unburied piping inspections during each generator run time <br /> Page 2 of the Designated Operator inspection reports demonstrates compliance with monthly <br /> inspections of the unburied piping <br /> See referenced inspection documentation below. <br /> Item#302 <br /> Notice of Violation <br /> HSC 25291(b)UST system incapable of detecting leak from primary into secondary containment(pre-Jul <br /> 2003). <br /> The H5: Fuel Polisher sensor was not working during the inspection. According to EHD records, the <br /> buried piping attaching the fuel polisher to the underground storage tank is still in place and operable. All <br /> secondary containment containing primary fuel lines needs to be monitored. Immediately get monitoring <br /> set up in the Fuel Polisher and submit the work order to the EHD. <br /> This is a minor violation <br /> RESPONSE: Inspection of H5: Fuel Polisher sensor scheduled and confirmed operational August <br /> 24, 2017. <br /> Should you have any questions relating to the underground storage tank system and this letter, please do <br /> not hesitate to ask either Masood Choudhury at(909) 620-5962 or myself. <br /> Sincerely, <br /> Michael Barber <br /> General Manager <br /> 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.