My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_2012-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 3:36:41 PM
Creation date
6/23/2020 6:47:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2017
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_2012-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
530
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-a. <br />'U"WES0 <br />-- engineering constructors, inc. <br />License # 703190 <br />4780 Cheyenne Way, Chino, CA 91710 p) 888-588-8737 f) 909-594-6169 www.sunwestengineering.com <br />August 28, 2014 <br />Verizon California, Inc. <br />Re: Cathodic Protection System Survey for the 6,000 -gallon Underground Storage Tank located at Manteca Central <br />Office, 430 West Center Street, Manteca, CA 95336 <br />Dear Sir or Madam: <br />The galvanic cathodic protection (CP) system at the above location includes four magnesium anodes connected <br />through a test station to the underground fuel tank, piping, tank hold down straps, and anchoring system. The CP <br />system was installed in June 1999. <br />The survey was conducted by measuring the structure -to -soil potentials at the locations described on the attached <br />data sheet. Potentials were measured with and without protective current applied using a digital multi -meter <br />connected between the test points, and a saturated copper/copper sulfate reference electrode (CSE) in contact with <br />the earth. Current flows were also measured between the anodes and the underground storage tank (UST), vent and <br />UST anchors. The potentials recorded met or exceed the minimum of --850 millivolts (mV) as specified by the National <br />Association of Corrosion Engineers (NACE). <br />This survey was conducted in accordance with the procedures and test methods described in NACE Standard <br />Recommended Practice RP0285-2002, Corrosion Control of Underground Storage Tank Systems by Cathodic <br />Protection, NACE Standard Practice SP0169-2007, Control of External Corrosion on Underground or Submerged <br />Metollic Piping Systems, and NACE Standard TM0101-2001, Measurement Techniques Related to Criteria for Cathodic <br />Protection on Underground or Submerged Metallic Tank Systems. <br />SunWest Engineering Constructors, Inc. appreciates the opportunity to assist you in this phase of your corrosion <br />mitigation program. If you have any questions, please contact Todd Hansen at (909) 247-6538 at your convenience. <br />Thank you, <br />Todd M. Hansen <br />NACE Certification No. 26518 <br />APR 2 , _ [' <br />
The URL can be used to link to this page
Your browser does not support the video tag.