Laserfiche WebLink
140714-197 <br />F. In -Tank Gauging / SIR Equipment: Check this box if tank gauging is used only for inventory control. <br />Check this box if no tank gauging or SIR equipment is installed. <br />This section must be completed if in -tank gauging equipment is used to perform leak detection monitoring. <br />ComD[ete the follow]no checklist: <br />IN <br />Yes <br />No` <br />Has all input wiring been inspected for proper entry and termination, including testing for ground faults? <br />N/A <br />Yes <br />Nd <br />Were all tank gauging probes visually inspected for damage and residue buildup? <br />e <br />Yes <br />TF No' <br />Was accuracy of system product level readings tested? <br />* <br />Yes <br />Na' <br />Was accuracy of system water level readings tested? <br />e <br />Yes <br />No' <br />Were all probes reinstalled properly? <br />For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? <br />Yes <br />No' <br />Were all items on the equipment manufacturer's maintenance checklist completed? <br />- in the section tf, beiaw, oescrioe now and wnen tnese denciencies were or wni De corrected. <br />G. Line Leak Detectors (LLD): 9 Check this box if LLDs are not installed. <br />Pn,nnlnfn li.® 4n11Muiean whm.4nc!• <br />IN AMMIlL'I <br />IN <br />Yes <br />No' <br />For equipment start-up or annual equipment certification, was a leak simulated to verify LLD pe f <br />N/A <br />that apply) Simulated leak rate: 03 g.p h.; E] 0.1 g.p.h ; []0.2 g.p.h. <br />Yes <br />TF No' <br />Were all LLDs confirmed operational and accurate within regulatory requirements? <br />Yes <br />No' <br />Was the testing apparatus properly calibrated? <br />Yes <br />No" <br />For mechanical LLDs, does the LLD restrict product flow it it detects a leak? <br />NIA <br />Yes <br />No' <br />For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? <br />WA <br />Yes <br />No" <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or <br />N/A <br />disconnected? <br />Yes <br />No. <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or <br />-; WA <br />fails a test? <br />Yes <br />Ej No' <br />For electronic LLDs, have all accessible wiring connections been visually inspected? <br />N/A <br />Yes <br />No' <br />Were all items on the equipment manufacturer's maintenance checklist completed? <br />In the Section H, below, describe how and when these deficiencies were or will be corrected. <br />H. Comments: <br />Monitoring System Certification Page 3 of 4 12/07 <br />3 <br />2/21/07 <br />