My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_2012-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 3:36:41 PM
Creation date
6/23/2020 6:47:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2017
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_2012-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
530
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />• <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, Califomia 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.oro/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility <br />Name: Verizon <br />Facility <br />Address: 430 W. Center, Manteca <br />ectim <br />DaInsite: Aug 28, 2014 <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and Safety Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />I Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M7) <br />703 <br />CCR 2643(d) <br />I Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report' for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, orMINOR-Notice to Comply) <br />This is a Routine and Monitoring System Certification Report. Following is a Minor - Notice to Comply <br />violation: 106 <br />106. Monthly Statistical Inventory Reconciliation (SIR) reports and Tank Integrity Testing reports as <br />declared on the Monitoring Plan (MP) uploaded on the California Environmental Reporting System <br />(CERS) website were available for review during this inspection. Also no dialing out at the monitoring <br />panel to meet the remote monitoring as declared on the MP uploaded to CERS. The monitoring and <br />response plans must be current and approved by the EHD. Immediately submit the above missing <br />reports to EHD and upload them to CERS, or log into CERS and update the required MP information <br />and submit for review by the EHD by 09/28/2014. Maintain an approved copy on site if access to CERS <br />is not always available. Observed technician corrected dialing up for remote monitoring requirement <br />(this section of the violation has been corrected on site. <br />NOTES <br />Observed Todd Hansen, ICC Cathodic Protection exp. 3/10/16, NACE cert. exp. 11/30/14) tested the <br />sacrificial anode today. Submit a copy of the report to CERS within 30 days of test. The anode must be <br />tested once every three years. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />�HPS FACILITY IS SUBJECT TO REINSPECTION AT ANYTIME AT EHD'S CURRENT HOURLY RATE. <br />
The URL can be used to link to this page
Your browser does not support the video tag.